![BYD Battery-Box Premium LVL 15.4 User Manual Download Page 32](http://html.mh-extra.com/html/byd/battery-box-premium-lvl-15-4/battery-box-premium-lvl-15-4_user-manual_2836966032.webp)
31
BATTERY
BOX
BATTERY-BOX
PREMIUM
LVL
•
Training in the installation and commissioning of electrical equipment
•
Knowledge of, and adherence to the locally applicable connection requirements,
standards and directives
•
Knowledge of, and adherence to this document and the associated system
documentation, including all safety instructions
7.1
Prerequisites
The inverter must be installed according to the interconnection diagram specified by
inverter manufacturer.
The power circuit breaker in the distribution system must be open
Check the wiring of the inverter and battery. See the Installation Instructions from
inverter.
Close all components. This protects all live components from accidental contact.
Close the DC fuse (if used)
7.2
Start the system
Before switch on the system, make sure the inverter does not connect to the grid.
Switch on the product
Press the button for 3 seconds, the LED starts to flash (0.5s white, 0.5s blue), then it
turns to glow (white). If fail to switch on the system, please check if all the electrical
connection is correct; if the electrical connection is correct, still unable to switch on,
please contact our local after sale service within 48 hours.
Communication configuration: Be Connect
•
Views and features of Be Connect application
Be Connect is an application designed to help user to finish BYD battery box
premium communication configuration, it can be downloaded from both android and
IOS platform. This application requires a WIFI connecting with BYD battery box
premium before using it, make sure that net cable between battery box premium and
BMU is well connected, so that the system can release a WIFI signal.
The name and password of WIFI are attached on last page of Quick Start Guide Book.