5 Minimum configuration with Sungrow

 

5.1 Minimum configuration with SH5K 

Inverter Firmware version: minimum required firmware version is V13. 
B-Box firmware version: minimum required firmware version for BMU is V4-10.

 

Identification label on package is V1.2

 

Shall bypass main circuit breaker when the system is off grid application. 

1 Phase on Grid 

Inverter Type 

B-Plus 2.5 

Cabinet 

SH5K 

≥2 

≥1 

1 Phase off Grid

3&1

 

Inverter Type 

B-Plus 2.5 

Cabinet 

SH5K 

≥2 

≥1 

Remark: Maximum quantity of B-Plus is 8, Cabinet quantity is 8. 

6 Minimum configuration with Selectronics 

 

6.1 Minimum configuration with SP PRO 

Inverter Firmware version: minimum required firmware version is V0.27. 
B-Box firmware version: minimum required firmware version for BMU is V4-10. 
Identification label on B-Box cabinet package: V2.2 

1 Phase on Grid 

Inverter Type 

B-Plus 2.5 

Cabinet 

SPMC481-AU 

≥2 

≥1 

SPMC482-AU 

≥2 

≥1 

1 Phase off Grid1&2 

Inverter Type 

B-Plus 2.5 

Cabinet 

SPMC481-AU 

≥5 

≥2 

SPMC482-AU 

≥6 

≥2 

Remark: Maximum quantity of B-Plus is 32, Cabinet quantity is 8. 

 

 

 
 
 
 
 
 
 
 

Summary of Contents for B-Box Res 10.0

Page 1: ...B Box Res 2 5 10 0 User Manual Rev 1 0 Feb 2018 Copyright BYD Lithium Battery Company Limited All rights reversed...

Page 2: ...1Alarm indicated on the BMU and the solution 10 8 2 Alarm displayed on B Plus 2 5 and the solution 10 8 3 Common issues displayed on inverter and the solution 12 9 Warranty 12 10 Registration 12 Appen...

Page 3: ...Sungrow 19 5 1 Minimum configuration with SH5K 19 Appendix 2 Common Issues Displayed on Inverter and Solutions 20 1 Alarm code displayed on the SRC of SMA sunny island and solution 20 2 Alarm displaye...

Page 4: ...to the product e g changes or modifications are only permitted with the express written permission of BYD Unauthorized alterations will void warranty claims BYD shall not be held liable for any damage...

Page 5: ...expose the battery to direct sunlight for extended periods of time Place battery in secure location away from children and animals Do not allow the battery power terminals to touch conductive objects...

Page 6: ...urrent adjustment 2 N Quantity of B Plus 2 5 battery Discharge current control under different temperatures Protect temp Resume temp Normal current A 10 50 0 7 1C N Remark 1 N Quantity of B Plus 2 5 b...

Page 7: ...P P 11 Cell voltage Single cell voltage 12 Failure Battery or BMS are broken need to be replaced 13 Alarm indicate that the battery is in abnormal status 14 Protect Battery stops charging or dischargi...

Page 8: ...s P N is U3A1 50P A 3 BMU BMU Battery management unit communicates with external equipment 5 3 General introduction of BMU BMU installed inside cabinet is battery management unit The function is to ma...

Page 9: ...running status ERR LED ERR ADDR Indicate error status ALM LED Alarm Indicate alarm status RJ45 terminal RS485 Communication ports Address ADDR Address needs to be set if they are connected in paralle...

Page 10: ...arly according to the following table with 0 5C 25A current for 1 hour after a long time of storage Recharge conditions when in storage Storage environment temperature Relative humidity of storage env...

Page 11: ...disconnected 1 Check RS485 cable and battery address 2 If the connection and the address are correct please contact the after service provider Flash 4 times Any of battery failures Check battery led s...

Page 12: ...it Contact the after service provider 7times Discharge over current protection Contact the after service provider 8times High temperature protection Contact the after service provider 9times Low tempe...

Page 13: ...n please refer to Appendix 2 in this user manual 8 4 Emergency Please cut off the power supply and turn off the battery in emergency 9 Warranty BYD provides warranty when the product is installed and...

Page 14: ...formation is required for timely customer service 2 Serial Number of Battery Box Cabinet 3 Serial Number of B Plus 4 Serial Number of BMS 5 Installation Date 6 Invoice Number If you have any questions...

Page 15: ...B Plus 2 5 Cabinet SI 3 0M 3 1 SI 4 4M 4 1 SI 6 0H 4 1 SI 8 0H 4 1 1 Phase off Grid2 Inverter Type B Plus 2 5 Cabinet SI 3 0M 3 1 SI 4 4M 3 1 SI 6 0H 5 2 SI 8 0H 5 2 3 Phase off Grid1 Inverter Type B...

Page 16: ...mum configuration with EM Inverter Firmware version minimum required firmware version for ARM is 03 B Box firmware version minimum required firmware version for BMU is V4 10 Shall bypass main circuit...

Page 17: ...3000 35 1 1 48 5000 70 1 1 3 Phase on Grid Inverter Type B Plus 2 5 Cabinet 48 3000 35 3 1 48 5000 70 3 1 1 Phase off Grid1 Inverter Type B Plus 2 5 Cabinet 48 3000 35 2 1 48 5000 70 3 1 3 Phase off G...

Page 18: ...00 110 100 100 1 1 48 10000 140 100 100 1 1 48 15000 200 100 100 1 1 3 Phase on Grid Inverter Type B Plus 2 5 Cabinet 48 5000 70 100 100 3 1 48 8000 110 100 100 4 1 48 10000 140 100 100 5 2 48 15000 2...

Page 19: ...Plus 2 5 Cabinet 48 3000 35 50 MPPT150 70 2 1 48 5000 70 100 MPPT150 100 3 1 3 Phase off Grid3 1 Inverter Type B Plus 2 5 Cabinet 48 3000 35 50 MPPT150 70 6 2 48 5000 70 100 MPPT150 100 9 3 Remark Max...

Page 20: ...1 Phase off Grid3 1 Inverter Type B Plus 2 5 Cabinet SH5K 2 1 Remark Maximum quantity of B Plus is 8 Cabinet quantity is 8 6 Minimum configuration with Selectronics 6 1 Minimum configuration with SP P...

Page 21: ...stem setting according to the guidelines F922 XA03DcLoVolt External Alarm Battery Low Voltage F923 XA04DcHiTmp External Alarm Battery High Temp F924 XA05DcLoTmp External Alarm Battery Low Temp F925 XA...

Page 22: ...ication fail Inverter and BMU communication failure 1 check whether the CAN communication cable has been connected correctly and tightly 2 Change BMU in cabinet 3 Alarm displayed on the screen of Sola...

Page 23: ...d Baolong Industrial Town Longgang Shenzhen 518116 China Local Contacts Australia Alps Power Pty Ltd Customer Service Mailbox service alpspower com au Telephone 61478 140 287 Address U201 15Chatham Ro...

Reviews: