21
3.
Please switch the ammeter to
Ω×1, and check control signal
s and
high-pressure signals impedance value. High-pressure signals are
100V
(
White
)
and
COM
(
Green
)
.
If the there are more than one high-pressure
signals, please inspect these high-pressure signals as well.
100V
(
White
)
&
【
RF OUT
(
Yellow
)
、
B+
(
Red
)
、
RF IN
(
Blue
)
、
G
(
Black
)】
COM
(
Green
)
&
【
RF OUT
(
Yellow
)
、
B+
(
Red
)
、
RF IN
(
Blue
)
、
G
(
Black
)】
☆
Usually, positive and negative (+/-) impedance values are high (above 500
Ω
)
unless there are any short-circuits. If that happens, use 1/2 troubleshooting
method to examine. Connect the cables to WMP-2100 after examining.
☆
After examining, turn on WMP-2100 and it will start auto-scanning. Make
sure all the decoders work properly then connect high-pressure signal lines
to a power amplifier.
☆
If more than two main consoles are connected, please make sure all the
connected apparatuses work properly. Next, inspect connection on
WMP-2100A according to
III. Linked control for two main consoles
on P.14.