Cleaning
Cleaning
Cleaning
Cleaning
Cleaning
Clean the regenerative container with drinking water if it is dirty.
For hygienically demanding applications
Twice a year
For standard applications
Once a year
Disinfection
Disinfection
Disinfection
Disinfection
Disinfection
F
F
F
F
For Rondomat D
or Rondomat D
or Rondomat D
or Rondomat D
or Rondomat DV
V
V
V
VGW only:
GW only:
GW only:
GW only:
GW only:
Disinfection if not used for more than 4 days
Power failure
Power failure
Power failure
Power failure
Power failure
If there is an extended power failure (8 hours), the unit starts operation with
a regeneration when the power returns.
If the power failure occurred during a regeneration, the controller regener-
ates the column in which the regeneration process was interrupted when
power returns.
Shutting down
Shutting down
Shutting down
Shutting down
Shutting down
BWT drinking water softening units are produced and supplied hygienically.
After start-up the ion exchanger resin tends to become infected if shut down
incorrectly and therefore to release organic substances.
Therefore, the procedure described below is required under the following
conditions:
If no water is available for more than 48 h (e.g. for modifications, the softe-
ning unit is disconnected from the drinking water network).
If the softening unit is not required for an extended period (more than
4 weeks, e.g. seasonal operation in a hotel).
Ideally, the softened water supply should be almost completely used up
before shutting the unit down.
The columns should only being flushed and not regenerated.
If this is not possible, the unit should be regenerated completely.
The water supply to the unit can now be shut off and the unit can be
disconnected from the power supply.
Reactivating the unit
Reactivating the unit
Reactivating the unit
Reactivating the unit
Reactivating the unit
after shutting down
See the Start-up item
The unit must be completely regenerated anyway (both columns for
2 column units).
We recommend hygienic maintenance by our after-sales service team after
the unit is shut down.
9 Operator responsibilities
9 Operator responsibilities
9 Operator responsibilities
9 Operator responsibilities
9 Operator responsibilities
You have purchased a durable and service-friendly product.
However, all technical equipment requires regular servicing to guarantee
optimal functioning.
Regular checks performed by the operator are required for the warranty
Regular checks performed by the operator are required for the warranty
Regular checks performed by the operator are required for the warranty
Regular checks performed by the operator are required for the warranty
Regular checks performed by the operator are required for the warranty
and proper functioning of the unit.
and proper functioning of the unit.
and proper functioning of the unit.
and proper functioning of the unit.
and proper functioning of the unit. The unit must be inspected regularly or, at
the latest, every 2 months depending on service and operating conditions.
On a regular basis, find out about the quality/pressure ratio of the water to be
treated. If the water quality changes, the settings may need to be changed.
Consult a specialist if this is the case.
Checks
Checks
Checks
Checks
Checks
The operator must perform the following checks regularly to guarantee that
the unit functions properly.
Check the network pressure/flow pressure
Check the network pressure/flow pressure
Check the network pressure/flow pressure
Check the network pressure/flow pressure
Check the network pressure/flow pressure
Once a week
Once a week
Once a week
Once a week
Once a week
Check/refill regenerative
Check/refill regenerative
Check/refill regenerative
Check/refill regenerative
Check/refill regenerative
According to use
According to use
According to use
According to use
According to use
Check brine containers for soiling
Check brine containers for soiling
Check brine containers for soiling
Check brine containers for soiling
Check brine containers for soiling
Every 2 months
Every 2 months
Every 2 months
Every 2 months
Every 2 months
Check for leaks, visual inspection
Check for leaks, visual inspection
Check for leaks, visual inspection
Check for leaks, visual inspection
Check for leaks, visual inspection
Every 2 months
Every 2 months
Every 2 months
Every 2 months
Every 2 months
Functional test/control unit displays
Functional test/control unit displays
Functional test/control unit displays
Functional test/control unit displays
Functional test/control unit displays
Every 2 months
Every 2 months
Every 2 months
Every 2 months
Every 2 months
Checking the water hardness
Checking the water hardness
Checking the water hardness
Checking the water hardness
Checking the water hardness
The hardness of untreated water entering the unit as well as the set hardness
of the blended water must be checked, logged at regular intervals and
corrected if need be (see Safety instructions and Starting the unit).
Checking the hardness of untreated water
Checking the hardness of untreated water
Checking the hardness of untreated water
Checking the hardness of untreated water
Checking the hardness of untreated water
Residential / Commercial buildings
Monthly
Industry / Boiler / Air conditioning
Once a week
Pre-treatment for membrane processes
Once a week
Checking the hardness of softened water / blended water
Checking the hardness of softened water / blended water
Checking the hardness of softened water / blended water
Checking the hardness of softened water / blended water
Checking the hardness of softened water / blended water
Residential / Commercial buildings
Monthly
Industrial
Depending on the requirement, daily for softened water
Boiler/air conditioning
Daily
Pre-treatment for membrane processes
Daily
Option
Option
Option
Option
Option
A Testomat F-BOB automatic hardness tester can be used to check the
hardness of the softened water / blended water and monitored via CIC.
Order no.: 11987
Maintenance
Maintenance
Maintenance
Maintenance
Maintenance
The replacement of wearing parts within the prescribed maintenance
The replacement of wearing parts within the prescribed maintenance
The replacement of wearing parts within the prescribed maintenance
The replacement of wearing parts within the prescribed maintenance
The replacement of wearing parts within the prescribed maintenance
intervals is also required for the warranty and proper functioning of the unit.
intervals is also required for the warranty and proper functioning of the unit.
intervals is also required for the warranty and proper functioning of the unit.
intervals is also required for the warranty and proper functioning of the unit.
intervals is also required for the warranty and proper functioning of the unit.
The unit must be serviced once a year. Communal units must be serviced
twice a year.
Maintenance and wearing parts
Maintenance and wearing parts
Maintenance and wearing parts
Maintenance and wearing parts
Maintenance and wearing parts
Hygienic cleaning of the brine container at least
Once a year
Inspect regeneration block
Once a year
Inspect non-return valve
Once a year
Inspect brine valve
Once a year
Inspect electrolysis cell
Once a year
Check low-salt level
Once a year
Charge Soft-Control battery
Once a year
Main membrane
Every 3 years
Electrolysis cell
Every 3 years
Regeneration block non-return valve
Every 3 years
Waste water valves
Every 3 years
Regeneration block
Every 5 years
Gauge slide
Every 5 years
Water meter cover
Every 5 years
Dilution unit
Every 5 years
Connection hoses
Every 5 years
Brine valve
Every 5 years
Brine pipeline
Every 5 years
Waste water hose
Every 5 years
Container
Every 10 years
We recommend that you enter into a maintenance agreement with your fitter
or the after-sales service department.