![BWT PERMAQ COMPACT 270 Series Installation And Operating Manual Download Page 31](http://html1.mh-extra.com/html/bwt/permaq-compact-270-series/permaq-compact-270-series_installation-and-operating-manual_2836820031.webp)
UK
31
Position No.
BWT PERMAQ
®
Compact plant 271-274
Recommended
spare parts
Article No.
Recommended
replacement
frequency
Membrane/pressure vessel
30
Pressure vessel
451202069
31
Membrane
1-4
451202040
*
32
U-lock
451202120
33
V-Cup seal for membrane
34
O-ring outside (large)
4-16
451202212
2 years
35
O-ring inside (small)
4-16
451404215
2 years
36
Push-in fitting, 10x¼”, base
1
454065010
3 years
36A
Push-in fitting, 12x¼”, base
1
454065012
3 years
37
End plate
2
451202117
3-5 years
Miscellaneous
-
10 mm plastic hose
1 m
454001010
3 years
-
-
-
-
12 mm plastic hose
20
µF
capacitor (Transport
motor
)
16
µF
capacitor (High pressure
motor
)
Filter wrench
1 m
1
1
454001012
750001270
750001860
321417100
3 years
Option
-
Filter housing, 10" complete
321401000
-
Carbon filter, 10"
321413000
½ year
-
Sensor (conductivity meter)
452536006
-
Conductivity meter
452525000
-
CIP tank complete
451404573
* Contact your local BWT dealer for detailed information.
Summary of Contents for PERMAQ COMPACT 270 Series
Page 1: ...BWT PERMAQ COMPACT 271 274 Reverse Osmosis Plant Installation and Operating manual UK ...
Page 2: ...UK 2 ...
Page 10: ...UK 10 9 2 3 Alarm Low raw water pressure 9 2 4 Alarm Transport pump ...
Page 11: ...UK 11 9 2 5 Indication Level low 9 2 6 Alarm Level high ...
Page 12: ...UK 12 9 2 7 The plant is not operating ...
Page 20: ...UK 20 13 1 P I Diagram ...
Page 21: ...UK 21 13 2 Layout Drawings ...
Page 22: ...UK 22 ...
Page 23: ...UK 23 ...
Page 24: ...UK 24 ...
Page 25: ...UK 25 13 3 Wiring Diagram ...
Page 26: ...UK 26 ...
Page 27: ...UK 27 ...