![BWT AQA smart Installation And Operating Manual Download Page 52](http://html1.mh-extra.com/html/bwt/aqa-smart/aqa-smart_installation-and-operating-manual_2836718052.webp)
52
EN
Water
softener
Type
AQA
smart
AQA smart C
Nominal diameter of the connection
DN
32 (G 1 1/4“ AG)
Nominal pressure (PN)
bar
10
Operating pressure
bar
2,5 - 8,0
Nominal flow in acc. with EN 14743 (DIN 19636)
m
3
/h
1,4 (1,7)
Pressure loss at nominal flow
bar
0,7
The values for capacity and consumption are the same for both systems
Control settings of the capacity
tP
1
2
3
Recommended area of use Residential units
1-2
3
4
Nominal capacity in acc. with EN 14743 m
3
x °d (mol)
9 (1,6)
13 (2,4)
18 (3,2)
Quantity of regenerating agent (approx.) kg
0,35
0,5
0,8
Regeneration, water requirement*
litre
27
39
50
Maximum flow**
m
3
/h 1,4
Quantity of resin
Liter
7
Supply of regenerating agent, max
kg
15
50
Network connection
V/Hz
230/50
Connected rating in operation / regeneration
W
4,0
Energy consumption pro regeneration
kWh
0,0013
Unit voltage
V
18 ~
Protective class
IP 53
Water temperature/Ambient temperature, min.-max.
°C
5 - 30 / 5 - 40
Air humidity
Non-condensing
Height
H
mm
630
1090
Width
B
mm 390
390
Depth, approx.
T
1
mm
470
470
Depth, approx.
T
2
mm
570
570
Connection height of overflow hose
S
mm
283
650
Connection height, approx.
A
mm
495
960
Connection width
mm
60
60
Sewer connection, at least
DN
50
50
Operating weight, approx.
kg
40
100
Production number with Multiblock X
6-501087
6-501093
Production number without Multiblock X
6-501092
-
Item number with Multiblock X in Austria
6-501090
12 Technical data
* Depending on the primary pressure
** Maximal flow: Short-term flow with which the soft water system can be operated. With a maximum flow
and completely closed blending valve, the soft water hardness is less than 10% of the input water hardness.