Check the system has been installed correctly.
Measure the water hardness
Measure and note the drinking water hardness
upstream of the softener using AQUATEST.
Brine treatment
Remove the cover plate (4).
Fill the supply cavity (5) with regenerating agent (salt
tablets as per DIN EN 973 type A, e.g. Clarosal or
Sanisal/Sanitabs).
Fill the brine chamber (6) with 4 litres of drinking
water.
Plug in.
The water supply must remain closed.
The display shows StArt and then alternates
between the capacity utilisation and weekday (1-
7) - time.
Let the basic fixing drain off (approx. 40 seconds).
The operating noise ends.
If regeneration begins automatically, cancel this by
pressing the OK button.
Open the water inlet!
Activate the start-up rinse
Keep pressed
until lbn appears in the display.
Rinsing for 1 minute (rinse time t1), then the valve
starts to work.
The system is ready to operate.
The capacity and the blending valve are preset. You
only need to readjust these if the water is particularly
hard (hardness greater than 22 °d) or if the water
is of average hardness (hardness less than 14 °d).
Ibn
5
4
6
e.g.
5 07:43
450 L
StArt