GasAlertClip Extreme English Instruction Sheet
D2139-3 Page 5
Trimmed and folded dimensions: 4.125 (w) x 5.875 (h)
Accessories
Test cap: GA-TC-1
The test cap accessory is designed to fit over the sensor when you test the
detector’s response to the target gas.
Infrared handheld printer: GPR-PRINTER
The printer accepts and prints stored gas alarm event data.
Automatic test station: GA-TS02
The test station is designed to automatically test response to gas.
Infrared USB adapter: GA-USB1
The adapter accepts stored gas alarm event data and transfers it to a PC.
IR DataLink: GA-USB2
Neck strap with safety release: GA-NS-1
Alligator clip (non-conductive): GA-AG-1
Hard hat clip: GA-HC-1
For use with alligator clip GA-AG-1 or GA-AG-2.
Belt clip: GA-CL-1
General Specifications
Shelf life
1 year before activation
Weight
76 g (2.7 oz.)
Instrument
dimensions
1.1 x 2.0 x 3.2 in. (28 x 50 x 81 mm)
Operating
temperature
H
2
S:
−
40 to
+
122
o
F /
−
40 to
+
50
o
C
CO:
−
22 to
+
122
o
F /
−
30 to
+
50
o
C
SO
2
:
−
22 to
+
122
o
F /
−
30 to
+
50
o
C
O
2
:
−
4 to
+
122
o
F /
−
20 to
+
50
o
C
Internal vibrating option operates to: +5
o
F /
−
15
o
C
Operating humidity
5% to 95% relative humidity
(non-condensing)
Audible alarm
≈
95 dB at 1 ft. (30 cm)
Visual alarm
Flashing, wide-angled alarm lens with quad red
LEDs plus alarm LCD readout.
Display
Liquid crystal display (LCD)
Sensor type
Electrochemical cells
Detection technique
Instantaneous alarm
Battery
Lithium, non-replaceable
Ratings and
certifications
Classified by UL to both U.S. and Canadian
Standards as intrinsically safe for Class I, Division
1, Group A, B, C, D and Class I, Zone 0, Group IIC
ATEX
:
CE 0539
g
II 2 G EEx ia IIC T4
DEMKO 03 ATEX 0321968
ATEX
:
CE 0539
g
II 1 G EEx ia IIB T4
DEMKO 03 ATEX 0321968
IECEx
CE: European Conformity
ABS Type Approved VA-348-169-X
Ingress protection
IP 66/IP 67
EMI/RFI
Complies with EMC Directives 89/336/EEC
Safety Specifications
Maximum operating
life
2 years after activation, assuming 3-5 minutes of
alarm time/day
Detection range
H
2
S: 0 to 100 ppm
CO: 0 to 300 ppm
O
2
: 0 to 30% by volume
SO
2
: 0 to 100 ppm
Alarm setpoints
Instant low and instant high
Calibration
H
2
S, CO, SO
2
: Not required
O
2
: Self-calibrating
Note: This product has been classified for use in atmospheres not more
than 21% v/v O
2
.
Event Logging Specifications
Number of stored
events
Up to 10 events encountered
Data transmission
method
Via infrared port to thermal printer or via IR USB
adapter to PC (for ordinary locations only)
Information
transmitted
Serial number
Life remaining
Self-tests performed
Total number and duration of all events
encountered
Last 10 alarm events:
Gas type and alarm level in ppm or %
Time elapsed since the alarm occurred in days,
hours, and minutes
Duration of alarm in minutes and seconds
Data transmission
time
45 seconds plus 10 seconds per record