background image

Get current Wi-Fi information and status
Send: WLAN+STATUS
Return: Current Status: SSID<current network name> Password<current password> 
Connected or Disconnected

 

OK 

Get the current Socket information and status:
Send: STATUS
Return: Current Status: Protocol<current protocol> IP<current target IP> Port<current port> 
Connected or Disconnected

 

OK 

WF-WM410

WiFi Wireless High 

Speed

 High 

Precision

 Inclinometer 

SOCKET socket settings and acquisition

The protocol can choose TCP or UDP protocol, the actual sending frequency (pack/s) of UDP can be higher
but the packet will be lost. Higher transmission frequency does not mean higher transmission speed (Byte/s)
or higher automatic output frequency upper limit (Hz) that can be set. Under normal circumstances, the limit
transmission speed using UDP is only slightly higher than that using TCP, but Using UDP can significantly
reduce the combined sending of multiple packets.

Set Socket information:
Send: SET+TCP or UDP+target IP+target port
Return: OK
Example: SET+TCP+192.168.0.1+4001

ZERO zero state setting and acquisition

Setting the relative zero point will use the current angle as the zero point reference, and setting the
absolute zero point will clear the relative zero point information and use the factory-set zero point as the
zero point reference.

Set relative zero point or absolute zero point
Send: ZERO+SET+RELATIVE (relative zero) or ABSOLUTE (absolute zero)
Return: OK

Bewis Sensing Technology LLC

   

  

  

  

   

   

   

   

   

   

   

    

    

    

    

    

    

    

    

    

    

    

    

      

      

      

 

                        

 

 

www.bwsensing.com

    Tel: 

+86 18906177922

Summary of Contents for WF-WM410

Page 1: ...WF WM410 WiFi Wireless High Speed High Precision Inclinometer Technical Manual...

Page 2: ...lems caused by connection loss caused by network abnormalities and server maintenance The sensitive mechanism adopts the latest technology the tilting unit of the micro electromechanical production pr...

Page 3: ...Introduction Connectors Protection level Housing material Install Aviation plug IP65 Magnesium aluminum alloy anode oxidation Three M4 screws Measuring range Measuring axis Accuracy Resolution Cross...

Page 4: ...ror between the actual angle and the Root mean square RMS of the measured angle of the sensor 16 times Supply voltage Charging voltage Charging current Operating current Battery capacity Electrical Sp...

Page 5: ...refer to actual size 109 97 65 36 72 5 4 Hole 105 Electrical connections Definition of Aviation Plug Wiring RED 1 4 2V Color function BLACK 3 GND GREEN 4 YELLOW 5 4 2 V 12 00V 12 00V 1 5 4 3 Sensor PO...

Page 6: ...installing the bottom cable of the sensor should be kept parallel or orthogonal to the rotation axis of the measured object This product can be installed horizontally or vertically vertical installat...

Page 7: ...gh Precision Inclinometer Debugging method 1 Serial data debugger SSCOM Download link http www daxia com sscom http www daxia com sscom sscom5 13 1 rar Instructions Open the software and select Englis...

Page 8: ...lect the BaudRate of 115200 Unselect HEXShow and SendHEX and select AddCrLf WF WM410 WiFi Wireless High Speed High Precision Inclinometer Bewis Sensing Technology LLC www bwsensing com Tel 86 18906177...

Page 9: ...C Manage Device Manager Ports COM LPT if there are multiple COM you can try them one by one but generally not COM1 WF WM410 WiFi Wireless High Speed High Precision Inclinometer Open source software Pu...

Page 10: ...rial port mode Enter the serial port number Serial line COM and baud rate Speed 115200 Click Open to open the serial port WF WM410 WiFi Wireless High Speed High Precision Inclinometer Bewis Sensing Te...

Page 11: ...f text to quickly copy and paste and right click after copying external text to paste Network debugging tools Note Due to the limited performance of the network debugging tools it is recommended to op...

Page 12: ...ion to reopen the listening Bewis Sensing Technology LLC www bwsensing com Tel 86 18906177922 Click Listen to start receiving data if there is a pop up window prompting network access please click All...

Page 13: ...the serial debugging tools section in the debugging method The pictures are all using the serial tool PuTTy and the sensor echo mode is set to the advanced mode Note Only after setting mode is turned...

Page 14: ...PuTTy that support Linux special characters as shown in the figure WF WM410 WiFi Wireless High Speed High Precision Inclinometer Prompt Most commands display further prompts when entering commands wit...

Page 15: ...s not IP address setting and obtaining Set the address the address is not case sensitive Send ADDR SET 8 bit hexadecimal address Return OK Example ADDR SET 0012ABCD Get current address Send ADDR STATU...

Page 16: ...not a common frequency the actual frequency may be slightly different from the set frequency and the current frequency read shall prevail The automatically output data content is the return informati...

Page 17: ...te s or higher automatic output frequency upper limit Hz that can be set Under normal circumstances the limit transmission speed using UDP is only slightly higher than that using TCP but Using UDP can...

Page 18: ...asic configuration SENSOR includes sensor address automatic output frequency and zero point information the network configuration NETWORK includes WLAN and Socket configuration all configurations incl...

Page 19: ...angle value for the compressed BCD code S is the symbol bit 0 positive 1 negative XXX is a three digit integer value YYYY is a small value Other axis data is the same For example 10268010 represents...

Page 20: ...charged The above red fonts are sign bits 0 positive 1 negative blue fonts are integer bits BCD code and purple fonts are decimal places BCD code 2 4 Set relative absolute zero Command 77 08 00 00 00...

Page 21: ...a content is the return information of reading all the data in the hexadecimal command 2 7 Set module address Command 77 0B 00 00 00 01 0F 12 34 56 78 2F Identifier 1 byte Frame Length 1 byte AddressC...

Page 22: ...Length 1 byte AddressCode 4 byte Command 1 byte Data 1 byte Checksum 1 byte 0x77 0x08 0x8A 2 10 Reboot Command 77 07 00 00 00 01 44 4C Identifier 1 byte FrameLength 1 byte AddressCode 4 byte Command...

Page 23: ...rtificate number 23919Q10455R0S CE certification certificate number M 2019 103 UY1151 RoHS Certificate G190930099 WF WM410 WiFi Wireless High Speed High Precision Inclinometer Executive standard Bewis...

Page 24: ...C Address Building 30 No 58 Xiuxi Road Binhu District Wuxi City Jiangsu Province China Tel Whatsapp 86 17606 118 008 Email support bwsensing com Website www bwsensing com WF WM410 WiFi Wireless High S...

Reviews: