![BW SENSING WF-WM410 Technical Manual Download Page 13](http://html1.mh-extra.com/html/bw-sensing/wf-wm410/wf-wm410_technical-manual_2836422013.webp)
②
EXIT
Turn off setting mode
Send
:EXIT
Return
:OK
③
HELP
Get command help
Send
:HELP
Return
:OK
WF-WM410
WiFi Wireless High
Speed
High
Precision
Inclinometer
Command list
String commands sent through the serial port
The following commands can configure the basic parameters of the sensor through the serial port. The serial
port parameters are 115200bps, 8-bit Frame Length, 1 stop bit, and no parity bit. For the use of the serial
port, please refer to the serial debugging tools section in the debugging method. The pictures are all using
the serial tool PuTTy and the sensor echo mode is set to the advanced mode.
Note: Only after setting mode is turned on, commands other than turning on setting mode can be used.
Tip: Any command sent in the setting mode will return OK or ERROR (actually "OK\r\n" or "ERROR\r\n").
①
Turn on the setting mode (send twice consecutively)
This command is no longer recognized after the setting mode is turned on, and will remain in the setting
mode unless it is reset or exited with EXIT.
Send: SET
Return: OK
Bewis Sensing Technology LLC
www.bwsensing.com
Tel:
+86 18906177922