                                            DESCRIPTION 

 

 
 

CWA-3 

CWA-2 

CWW-2 

CWA-34 

CWW-34 

Voltage AC 

120 

120 

120 

208/230 

208/230 

Circuit Breaker 

20 A, if 2

nd

 

pump + 15 A 

15 A + 

1 pump 15 A or 

2 pumps 20 A 

15 A + 

1 pump 15 A or 

2 pumps 20 A 

15 A + 

1 pump 15 A or 

2 pumps 20 A or 

3 pumps 20 A + 15 A 

15 A + 

1 pump 15 A or 

2 pumps 20 A or 

3 pumps 20 A + 15 A 

Plug (NEMA) 

2 x 5-15P * 

2 x 5-15P * 

2 x 5-15P * 

1 x 6-15P 

 1 x 5-15P * 

1 x 6-15P 

 1 x 5-15P * 

Running 

8.1 A 

10.5 A 

9.2 A 

6.5 A 

5.83 A 

BTU 

3120 

4610 

5800 

5420 

6700 

Refrigerant 

R-134a 

R-404a 

R-404a 

R-134a 

R-404a 

Charge 

18 oz. 

19 oz. 

18 oz. 

16 oz. 

21 oz. 

Tank Capacity 

12 gal. 

12 gal. 

12 gal. 

12 gal. 

12 gal. 

Foam insulation 

1” 

1” 

1” 

1” 

1” 

Weight 

106 lb 

113 lb 

113 lb 

134 lb 

134 lb 

Pressure 

approximate 

18 low 

150 high 

55 low 

255 high 

55 low 

265 high 

18 low 

150 high 

55 low 

265 high 

Pump 

(Gravity Fed) 

80 GPH 

(Gear) 

80 GPH 

(Gear) 

80 GPH 

(Gear) 

80 GPH 

(Gear) 

80 GPH 

(Gear) 

Dimensions 

(inches)** 

H: 29.0 

W: 26.5 

D: 17.0 

H: 29.0 

W: 26.5 

D: 17.0 

H: 29.0 

W: 26.5 

D: 17.0 

H: 29.0 

W: 26.5 

D: 17.0 

H: 29.0 

W: 26.5 

D: 17.0 

* 1 extra plug 5-15P  per additional pump.  **Dimensions include pump and motor. 

Summary of Contents for BVL-056

Page 1: ...BVL Power Pack Service Specification Manual Manufactured by BVL Controls Ltd...

Page 2: ...HP R 404a 208 230 VAC WATER COOLED CWW 2 1 2 HP R 404a 120 VAC CWW 34 3 4 HP R 404a 208 230 VAC DESCRIPTION COOLING DISTANCE from cooler to faucet ECO 025 UP TO 25 of cooling line or ice tower ECO 03...

Page 3: ...83 A BTU 3120 4610 5800 5420 6700 Refrigerant R 134a R 404a R 404a R 134a R 404a Charge 18 oz 19 oz 18 oz 16 oz 21 oz Tank Capacity 12 gal 12 gal 12 gal 12 gal 12 gal Foam insulation 1 1 1 1 1 Weight...

Page 4: ...13 oz 12 oz 15 oz 10 oz 10 oz Tank Capacity 3 gal 3 gal 8 gal 3 gal 8 gal Foam insulation 0 5 1 0 5 0 5 0 5 Weight 60 lb 65 lb 95lb 97 lb 92 lb Pressure approximate 18 low 150 high 18 low 150 high 18...

Page 5: ...404a R 404a R 404a Charge see label on unit 5 lb 5 lb 5 lb 6 lb 6 lb 6 lb Tank Capacity 28 gal 28 gal 28 gal 28 gal 28 gal 28 gal Foam insulation 1 1 1 1 1 1 Weight 257 lb 277 lb 297 lb 275 lb 295 lb...

Page 6: ...Triple Motor Bath Option Used With CWA or CWW Top view for CWA 3 CWA 2 CWA 34 and also CWW units 2 PUMPS 3 PUMPS Triple Quadruple Motor Bath Option Used With CWA 100 and 175 Top view for CWA 100 and...

Page 7: ...account and will be credited upon receipt of the defective part In Canada BVL Controls Ltd 661 de la Sabliere Bois des Filion Quebec Canada J6Z 4T2 Phone 1 866 BVL CONTROLS 285 2668 Direct Line 450 9...

Page 8: ...the pump before filling the tank The pump must always run to have a constant agitation in the tank and avoid damaging the compressor 6 Replace the cover on top of the tank 7 Before plugging the power...

Page 9: ...2 gallons 2 x 4 liters for the CMV 030 and add water until just below the overflow 6 Before plugging the pump ensure that the installation and connections have been made to required specification Aft...

Page 10: ...always use the lifting handles to raise the unit and pour 3 gallons 3 X 4 liters of glycol 100 in the tank and add water until just below the overflow 6 Before plugging the pump s ensure that the ins...

Page 11: ...dles to raise the unit and pour 3 gallons 3 X 4 liters of glycol 100 in the tank and add water until just below the overflow 6 Before plugging the pump s ensure that the installation and connections h...

Page 12: ...ircuit Repeat step 3 and 4 for each pump 5 Remove the unit from the top of the tank always use the lifting handles to raise the unit and pour 3 gallons 3 X 4 liters of glycol 100 in the tank and add w...

Page 13: ...d pump in a closed circuit and always run it 24 hours a day to have a constant agitation in the tank and avoid damaging the compressor 5 Remove the unit from the top of the tank always use the lifting...

Page 14: ...every year except in very hot areas where it should be changed every six 6 months 1 Check liquid monthly a If level is low fill with water b If ice builds up remove one gallon of water and replace wit...

Page 15: ...cooler B Check applied pressure to barrel C Check equipment D Warm product lines A Adjust cooler temperature between 34 and 36 F B Adjust setting on regulator for proper pressure C Check the physical...

Page 16: ...n reservoir for liquid flow Replace pump B Replace motor C Refer to 2 D Remove from any hot water pipes or kitchen area with stove or glass washer E Remove lines from PVC thoroughly dry PVC and repair...