BVA PA1500M Instruction Manual Download Page 3

3

•  Study,  understand,  and  follow  all 

instructions provided with and on this 

device before use.

•  All WARNING statements must be 

carefully  observed  to  help  prevent 

personal injury.

•  No alteration shall be made to this 

device.

•  Always  wear  protective  gear  when 

operating hydraulic equipment.

•  Keep hydraulic equipment away from 

flames and heat. Hydraulic fluid can 

ignite  and  burn.  Do  not  operate  if 

leaks are detected.

• 

Crush Hazard. 

Keep hands and feet 

away from loading area. Avoid pinch 

points  or  crush  points  that  can  be 

created by the load, cylinder, or any 

equipment of system.

• To avoid crushing and related injuries:

  NEVER  work  on,  under  or  around 

a  lifted  load  before  it  is  properly 

supported by appropriate mechanical 

means.  Never  rely  on  hydraulic 

pressure alone to support load.

!

   

WARNING

HYDRAULIC PUMPS

•  The  user  must  be  a  qualified  operator  familiar  with  the 

correct operation, maintenance, and use of pumps. Lack of 

knowledge in any of these areas can lead to personal injury.

• Do not exceed rated capacity of the pump or any equipment 

in the system. 

• Never attempt to lift a load weighing more than the capacity 

of the cylinder. 

• Burst hazard exists if hose or connection pressure exceeds 

rated pressure.

•  Do  not  subject  the  pump  and  its  components  to  shock 

loads.

• Inspect pump, cylinder, hoses and connections before each 

use  to  prevent  unsafe  conditions  from  developing.  Do  not 

use  if  they  are  damaged,  altered  or  in  poor  condition.  Do 

not  operate  the  system  with  bent  or  damaged  coupler  or 

damaged threads.

•  Never  hold  or  stand  directly  in  line  with  any  hydraulic 

connections while pressurizing.

• Use gauge or other load measuring instrument to verify load. 

• Never attempt to disconnect hydraulic connections under 

pressure. Release all line pressure before disconnecting 

hoses.

•  Use only approved accessories and approved hydraulic fluid.

•  Never attach ANY component not authorized by manufacturer.

•  Always ensure that the chosen application is stable to work 

on and around.

• Do not connect to application  which can return more oil to 

the reservoir than the pump reservoir can hold. 

•  Do  not  connect  pump  to  hydraulic  system  powered  by 

another pump.

•  This device is not suitable for use as support device! As 

the system load is lifted, use blocking and cribbing to guard 

against a falling load.

•  All  personnel  must  be  clear  before  lowering  load  or 

depressurizing the system.

•  Never try to disassemble a hydraulic cylinder, refer repairs 

to qualified, authorized personnel.

HYDRAULIC HOSES & FLUID TRANSMISSION LINES

•  Avoid short runs of straight line tubing. Straight line runs 

do not provide for expansion and contraction due to 

pressure and/or temperature changes.

• Reduce stress in tube lines. Long tubing runs should be 

supported by brackets or clips.  Before operating the pump, 

tighten  all  hose  connections  with  proper  tools.  Do  not 

overtighten. Connections should only be tightened securely 

and leak-free. Overtightening can cause premature thread 

failure or high pressure fittings to burst.

• Should a hydraulic hose ever rupture, burst or need to be 

disconnected, immediately shut off the pump and release 

all pressure. Never attempt to grasp a leaking pressurized 

hose with your hands. The force of escaping hydraulic fluid 

can inflict injury.

• Do not subject the hose to potential hazard such as fire, 

sharp objects, extreme heat or cold, or heavy impact.

•  Do not allow the hose to kink, twist, curl, crush, cut or bend 

so tightly that the fluid flow within the hose is blocked or 

reduced. Periodically inspect the hose for wear.

•  Do not pull, position or move setup by the hose.

•  Hose material and coupler seals must be compatible with 

hydraulic fluid used. Hoses also must not come in contact 

with  corrosive  materials  such  as  battery  acid,  creosote-

impregnated objects and wet paint. Never paint a coupler 

or hose.

• FAILURE TO HEED THESE WARNINGS MAY RESULT IN 

PERSONAL INJURY AS WELL AS PROPERTY DAMAGE.

Summary of Contents for PA1500M

Page 1: ...l 888 332 6419 Fax 816 891 6599 E mail sales bvahydraulics com Website www bvahydraulics com Maximum Operating Pressure 10 000 PSI PA1500M M0 rev 08 07 This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death ...

Page 2: ...rom service immediately until checked out by a BVA Hydraulics authorized service center Owners and operators of this equipment shall be aware that the use and subsequent repair of this equipment may require special training and knowledge PRODUCT DESCRIPTION BVA Hydraulics Double Acting Air Hydraulic Pump is engineered to meet most industrial standards for Performance and Safety It is an air hydrau...

Page 3: ...r attach ANY component not authorized by manufacturer Always ensure that the chosen application is stable to work on and around Do not connect to application which can return more oil to the reservoir than the pump reservoir can hold Do not connect pump to hydraulic system powered by another pump This device is not suitable for use as support device As the system load is lifted use blocking and cr...

Page 4: ...pressure load or position is reached Always monitor pressure load or position using suitable equipment Pressure may be monitored by means of optional manifolds and gauges contact BVA Hydraulics Load may be monitored by means of a load cells and digital indicators Note Do not continue to operate pump after cylinder plunger is fully extended or retracted 5 Release the foot pedal will stop the pump fl...

Page 5: ...per level Poor performance Fluid level in pump is low Ensure proper fluid level 5 MAINTENANCE Important Use only a good quality hydraulic jack fluid Never use brake fluid transmission fluid turbine oil motor oil alcohol glycerin etc Use of other than good quality hydraulic oil will void warranty and damage the pump hose and application We recommend Mobil DTE 13M or equivalent 1 Inspect hoses and conne...

Page 6: ...nd position in the assembly sequence Note To ensure safe and reliable performance replace worn or damaged parts with BVA Hydraulics Authorized Replacement Parts only MODEL PA1500M Air Hydraulic Pump Service Parts SFA Companies 10939 N Pomona Ave Kansas City MO 64153 Tel 888 332 6419 Fax 816 891 6599 E mail sales bvahydraulics com Website www bvahydraulics com ...

Page 7: ...on spring 1 32 A17 5 1603 300 Relief valve screw 1 33 601 7 0008 009 Steel ball 1 34 A59 6 1015 108 Oil entrance valve 1 35 520 8 0134 101 Filter 1 36 Gasket 1 37 A57 6 1601 107 Oil reservoir 1 38 649 1 0060 122 Allen screw 4 Item Part Number Description Qty 39 A57 6 1002 105 End plate air motor 1 40 A17 6 2105 108 Washer 2 41 A17 4 2100 500 Air motor piston 1 42 A57 6 1003 107 Cylinder air motor ...

Page 8: ...VA Hydraulics product fails due to material defect in workmanship you may contact SFA for disposition In such cases the customer s sole and exclusive remedy for any breach or alleged breach of warranty is limited to the repair or replacement of the defective product Under no circumstances is BVA Hydraulics liable for any consequential or incidental damage or loss whatsoever THIS WARRANTY IS LIMITE...

Reviews: