background image

User Manual

 

 

 

5.

 

The waterproof grade of this baking oven is Generic Category, therefore, it  is for indoor 
operation only. Placing the baking oven at a location with a spray of water or cleaning it 
with water jetting is strictly prohibited.

 

 
6.

 

The mode of power supply connection for this device is X-mode, users are permitted to 
change the wires for power supply on their own decision, but the wires must be the cable 
type Yzw or Yow with rubber-protection cover.

 

 
7.

 

Periodic check should be made on the electrical insulation and conductor connection, at 
least once every half a year.

 

 
8.

 

The baking oven should be placed at a dry and drafty location, and should be kept clean. 
When the surface gets dirty, clean it with water plus a little chemical neutral detergent, and 
dry it properly with wet cotton cloth.

 

 
9.

 

In case that the baking oven is out of operation for a long-term period, it should be kept 
clean and placed at a location that is dry and drafty.

 

 

 

 

 

 
 
 
 
 
 

Summary of Contents for OVP-1224

Page 1: ...USER MANUAL Electric Oven Proofer OVP 1224...

Page 2: ...the power supply on and the heat emitting tube in operation the electric connections of the main power supply will be automatically Switched off so as to avoid the occurrence of fire and electric shoc...

Page 3: ...ed off immediately in case of any malfunction of the baking oven Check and repair should be carried out by qualified professional personnel Unqualified curbstone people should not make bold to open th...

Page 4: ...decision but the wires must be the cable type Yzw or Yow with rubber protection cover 7 Periodic check should be made on the electrical insulation and conductor connection at least once every half a y...

Page 5: ...e the temperature controllers The color and luster of food on the same layer or different layers are not consistent 1 Check for the tightness of the closed door 2 The voltages of three phases are not...

Page 6: ...for further reference Key Technical Parameters Type Voltage V Temperature Range Power Rating kw Overall Dimension L W H mm Production Capacity kg h Weight kg OVP 1224 220V 50Hz 20 110 2 6 500 730 1610...

Page 7: ...e that the red power supply indicator lamp is on and that the machine fails to operate even if the temperature and humidity control knobs have been adjusted please check for water level inside the wat...

Page 8: ...t is of X type In case of replacing the power supply wires rubber sheath wires with specification similar to that of the wire type Yzw1 5mm2 that has been equipped for this machine must be adopted Ele...