2. S2:
Configuration Settings
Explanation
S2-1 (CONV)
Off = disabled
On = enabled
“Off” means that a 1 second
Stop
pulse will be sent
upstream in response to a
Stop
input from the
conveyor.
“On” means that the
Stop
sent upstream will be in
effect as long as a
Stop
input is received from the
conveyor.
S2-2 (UPSTR)
Off = disabled
On = enabled
“Off” means that a 1 second
Stop
pulse will be sent
upstream in response to a
Stop
input from the
upstream machine.
“On” means that the
Stop
sent upstream will be in
effect as long as a
Stop
input is received from the
upstream machine.
S2-3 (DNSTR)
Off = disabled
On = enabled
“Off” means that a 1 second
Stop
pulse will be sent
upstream in response to a
Stop
input from the
downstream machine.
“On” means that the
Stop
sent upstream will be in
effect as long as a
Stop
input is received from the
downstream machine.
S2-4 (FPSTOP)
Off = disabled
On = enabled
“Off” means that a 1 second
Stop
pulse will be sent
upstream in response to a
Stop
input from the front
panel
Stop
button.
“On” means that the
Stop
sent upstream will be in
effect as long as a
Stop
input is received from the front
panel
Stop
button.
S2-5 (CONTR)
Off = disabled
On = enabled
“Off” means that a 1 second
Stop
pulse will be sent
upstream in response to a
Stop
input from the control
computer.
“On” means that the
Stop
sent upstream will be in
effect as long as a
Stop
input is received from the
control computer.
S2-6 (JAM)
Off = disabled
On = enabled
“Off” means that a 1 second
Stop
pulse will be sent
upstream in response to a
Stop
input from the Jam
Detector.
“On” means that the
Stop
sent upstream will be in
effect as long as a
Stop
input is received from the Jam
Detector.
Buskro Ltd.
BK7IB Inline Base
Summary of Contents for BK7IB-2
Page 1: ...BK7IB 2 Inline Base Part No 9105171 User s Guide V1 0 ...
Page 5: ...General Information Buskro Ltd BK7IB Inline Base Chapter 1 1 0 General Information ...
Page 13: ...Operator Instructions Buskro Ltd BK7IB Inline Base Chapter 2 2 0 Operator Instructions ...
Page 22: ...BK7IB 2 Integration Buskro Ltd BK7IB Inline Base Chapter 3 3 0 BK7IB Integration ...
Page 25: ...Electrical System Buskro Ltd BK7IB Inline Base Chapter 4 4 0 Electrical System ...