11/24
BUSHRANGER
TM
X-16
PROBLEM DESCRIPTION
CAUSES
CORRECTIONS
Leakage through the cylinder
upper part.
Worn or dried out piston cup. Replace or lubricate the
piston cup.
After pumping and pressurizing the
chamber, as you operate the lever
it drops fast.
Cylinder valve not sealing
properly due to wear or
impurities.
Clean or replace
the valve.
After pumping and pressurizing
the chamber, the lever rises slowly
when released
.
Chamber valve not sealing
properly due to wear or
impurities.
Clean or replace the
chamber
.
Put about 2 litres of water in the tank. While operating the pumping lever,
look into the tank to see how the problem arises.
Refer to the table below.
TROUBLESHOOTING