INSTALLATION IN A CAVITY WITH THE MOUNTING KIT 

DC-L fridges are designed to be installed in a cavity. We recommend allowing 
a minimum 5mm gap on the left side, right side and above the fridge cabinet 
when installing. A minimum gap of 50mm is recommended for the rear. Refer 
to the following table and diagram for the recommended cut-out dimensions. 
 
 

 

            SIDE   

 

 

 

       FRONT 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

MODEL 

CUT-OUT CAVITY DIMENSIONS (MM) 

WIDTH

 

DEPTH

 

HEIGHT

 

DC190-L 

610 

575 

1385 

DC285-L 

610 

675 

1555 

 

 
 
 
 
 
 
 
 
 

Summary of Contents for Arcticold DC-L

Page 1: ...User Manual Operating Instructions DC L Fridges CARAVAN MARINE RV OFFGRID ...

Page 2: ...ified sine wave inverter to operate your fridge PRIOR TO INSTALLATION DELIVERY At delivery please check that the fridge is complete and is not damaged in any way Remove all packaging and securing tapes from the fridge To avoid injury and causing damage to the appliance be extremely cautious when using sharp or pointed tools to complete this task Do not connect an appliance that has been damaged co...

Page 3: ...ring is insufficient your fridge may not perform correctly or may be even be damaged CROSS SECTION IN MM2 MAXIMUM LENGTH OF WIRE IN METRES 12 V 24 V 2 5 2 5 5 4 4 8 6 6 12 10 10 20 Any switches must have a breaking load not less than 20 A on 12 V or 10 A on 24 volts Ensure the wiring polarity is correct Connect the red wire to the positive terminal and the black wire to the negative terminal Never...

Page 4: ... minimum 5mm gap on the left side right side and above the fridge cabinet when installing A minimum gap of 50mm is recommended for the rear Refer to the following table and diagram for the recommended cut out dimensions SIDE FRONT MODEL CUT OUT CAVITY DIMENSIONS MM WIDTH DEPTH HEIGHT DC190 L 610 575 1385 DC285 L 610 675 1555 ...

Page 5: ...it can be affixed to the front of the cavity OPERATING THE FRIDGE THERMOSTAT Turn the thermostat knob around from 0 to power up the fridge The cooling level can be set between 1 and 7 7 is the coldest setting and 1 is the warmest EQUALISING THE FRIDGE During the first 24 hours of operation your compressor will operate for longer than usual This process allows the internal air temperature food drin...

Page 6: ...p the doors of the fridge ajar when the fridge is not in use to allow fresh air to circulate inside the fridge compartment DEFROSTING Defrosting needs to be carried out when the ice layer reaches a thickness of 5mm Set the thermostat to 0 and move your food and beverages to another cool place Do not use any objects to remove the ice or frost it must be allowed to melt naturally Once the ice has me...

Page 7: ...evel to drop by as much as 2 V This occurs especially if the wiring in insufficient or if there is a loose connection somewhere If this occurs your fridge may exhibit a continuous start stop start pattern If so have your wiring checked by an electrician when under a 10 A load GENERAL TROUBLESHOOTING Check Correct power supply The built in fuse The voltage to the compressor is still 12V when a 10 A...

Page 8: ...ECIFICATIONS DC190 L DC285 L COMPRESSOR Secop BD50 Secop BD50 VOLTAGE 12 V 24 V DC 12 V 24 V DC REFRIGERANT 170g R134a 190g R134a EXTERNAL DIMENSIONS mm W 600 D 600 H 1380 W 600 D 700 H 1550 NETT WEIGHT 50 kg 62 kg ...

Page 9: ...ustomer This warranty does not apply to damage or wear to the product caused by accident abuse misuse neglect unauthorized alteration or repair or if the product was not used in accordance with Bushman printed installation and operating instructions To obtain service under this warranty the defective product must be returned to Bushman together with a copy of the original purchase receipt Any prod...