Troubleshooting | 12
Instruction Manual SECO SV_SD1010-1025C_SV_SD1040D_EN_en
27 | 32
Problem
Possible Cause
Remedy
The machine runs very noisily.
The machine runs in the wrong
direction
●
Check the direction of rota-
tion.
Defective bearings.
●
Repair the machine (contact
Busch).
The machine runs too hot.
Insufficient cooling.
●
Remove dust and dirt from
the machine.
Ambient temperature too high.
●
Observe the permitted am-
bient temperature.
The internal filters (IIF, IDF) are
partially clogged.
●
Replace the filter cartridge.
The inlet filter (optional) is par-
tially clogged.
●
Replace the filter cartridge.
For the solution of problems not mentioned in the troubleshooting chart contact your Busch repre-
sentative.
* The vane type acc. to the specification (only for the SV 1025 C / SV 1040 D)