7 | Maintenance
14 / 28
0870169116_RH0003-0021B_-0002_IM_en
Continuous suction
pressure
Maximum operating time
RH 0003 B
(with OMS 0003)
RH 0010-0021 B
(with OMS 0021)
100 hPa
Within 23 hours
Within 8 hours
80 hPa
Within 25 hours
Within 13 hours
53 hPa
Within 31 hours
Within 25 hours
27 hPa
Within 35 hours
Within 42 hours
6.2 Conveying Condensable Vapours
Water vapour within the gas flow is tolerated within certain limits. The conveyance of
other vapours shall be agreed upon with Busch.
If condensable vapours are to be conveyed:
• Make sure that the gas ballast valve is open.
Before process:
• Warm up the machine for approximately half an hour.
After process:
• Operate the machine for approximately another half an hour.
7
Maintenance
WARNING
Machines contaminated with hazardous material.
Risk of poisoning!
Risk of infection!
If the machine is contaminated with hazardous material:
• Wear appropriate personal protective equipment.
CAUTION
Hot surface.
Risk of burns!
• Prior to any action requiring touching the machine, let the machine cool down first.
• Shut down the machine and lock against inadvertent start up.
• Vent the connected lines to atmospheric pressure.
• Disconnect all connections.
7.1 Maintenance Schedule
The maintenance intervals depend very much on the individual operating conditions. The
intervals given below are desired to be considered as starting values which should be
shortened or extended as appropriate. Particularly heavy duty operation, such as high
dust loads in the environment or in the process gas, other contamination or ingress of
process material, can make it necessary to shorten the maintenance intervals significant-
ly.