Maintenance | 8
Instruction Manual R5 RB_RC 0021 C_EN_en
17 | 32
8.1
Maintenance Schedule
The maintenance intervals depend very much on the individual operating conditions. The intervals
given below are considered as starting values which should be shortened or extended as appropri-
ate. Particularly harsh applications or heavy duty operation, such as high dust loads in the environ-
ment or in the process gas, other contamination or ingress of process material, can make it neces-
sary to shorten the maintenance intervals significantly.
Maintenance work
Interval
Normal application
Harsh application
●
Check the oil level, see
Daily
●
Check the machine for oil leaks - in case of
leaks have the machine repaired (contact Bus-
ch).
In case of an inlet filter being installed:
●
Check the inlet filter cartridge, replace if neces-
sary.
Monthly
●
Change the oil*, the oil filter* (OF) and the ex-
haust filters (EF).
Max. after 4000 hours,
at the latest after 1
year
Max. after 2000
hours, at the latest
after 6 months
●
Contact Busch for an inspection.
If required, overhaul the machine.
Every 5 years
* Service interval for synthetic oil, shorten the interval when using mineral oil, contact Busch Service
8.2
Oil Level Inspection
●
Shut down the machine.
●
When the machine is stopped, wait 1 minute before checking the oil level.
MAX
MIN
MAX
MIN
MAX
MIN
●
11].
8.3
Oil Change
NOTICE
Use of an inappropriate oil.
Risk of premature failure!
Loss of efficiency!
●
Only use an oil type which has previously been approved and recommended by Busch.