background image

14 | EU Declaration of Conformity

20 / 24

0870168409_MV0602B_O2_A0000_IM_en_MD

14 EU Declaration of Conformity

This Declaration of Conformity and the CE-mark affixed to the nameplate are valid for the machine within the
Busch scope of delivery. This Declaration of Conformity is issued under the sole responsibility of the manufac-
turer.
When this machine is integrated into a superordinate machinery the manufacturer of the superordinate ma-
chinery (this can be the operating company, too) must conduct the conformity assessment process for the su-
perordinate machine or plant, issue the Declaration of Conformity for it and affix the CE-mark.

The manufacturer

Busch Produktions GmbH
Schauinslandstr. 1
DE-79689 Maulburg

declares that the machine(s): 

MINK ‘Oxygen’ MV 0602 B

fulfil(s) all the relevant provisions from European directives:

– ‘Machinery’ 2006/42/EC

– ‘Electromagnetic Compatibility’ 2014/30/EU

– ‘RoHS’ 2011/65/EU Restriction of the use of certain hazardous substances in electrical and electronic

equipment (incl. all related applicable amendments)

and comply(-ies) with the following designated standards that have been used to fulfil those provisions:

Standard

Title of the Standard

EN ISO 12100 : 2010

Safety of machinery - Basic concepts, general principles of design

EN ISO 13857 : 2019

Safety of machinery - Safety distances to prevent hazard zones being
reached by the upper and lower limbs

EN 1012-1 : 2010
EN 1012-2 : 1996 + A1 : 2009

Compressors and vacuum pumps - Safety requirements - Part 1 and Part 2

EN ISO 2151 : 2 : 2008

Acoustics - Noise test code for compressors and vacuum pumps - Engineer-
ing method (grade 2)

EN IEC 60204 : 2019

Safety of machinery - Electrical equipment of machines - Part 1: General re-
quirements

EN IEC 61000-6-2 : 2019

Electromagnetic compatibility (EMC) - Generic standards. Immunity for in-
dustrial environments

EN IEC 61000-6-4 : 2019

Electromagnetic compatibility (EMC) - Generic standards. Emission stand-
ard for industrial environments

EN ISO 13849-1 : 2015 

(1)

Safety of machinery - Safety-related parts of control systems - Part 1: Gen-
eral principles for design

(1)

 In case control systems are integrated.

Legal person authorized to compile the technical file 
and authorized representative in the EU 
(if the manufacturer is not located in the EU):

Busch Dienste GmbH
Schauinslandstr. 1
DE-79689 Maulburg

Maulburg, 18.05.2021

Dr. Martin Gutmann

General Manager

Summary of Contents for Mink Oxygen

Page 1: ...Get technical data instruction manuals service kits Instruction Manual Mink Oxygen Claw Vacuum Pumps MV 0602 B 0870168409 A0000_en Original instructions Modifications reserved 22 06 2021 ...

Page 2: ...ansport 6 4 Storage 7 5 Installation 7 5 1 Installation Conditions 8 5 2 Connecting Lines Pipes 9 5 2 1 Suction Connection 9 5 2 2 Discharge Connection 9 5 3 Filling Oil 10 5 4 Electrical Connection 10 5 4 1 Wiring Diagram Three Phase Motor 11 6 Commissioning 12 7 Maintenance 13 7 1 Maintenance Schedule 14 7 2 Oil Level Inspection 14 7 3 Cleaning from Dust and Dirt 15 8 Overhaul 16 9 Decommissioni...

Page 3: ...been designed and manufactured according to state of the art meth ods Nevertheless residual risks may remain This instruction manual highlights po tential hazards where appropriate Safety notes and warning messages are tagged with one of the keywords DANGER WARNING CAUTION NOTICE and NOTE as follows DANGER indicates an imminent dangerous situation that will result in death or serious injuries if n...

Page 4: ... CAI Cooling air inlet OFP Oil fill plug Venting valve CAO Cooling air outlet OSG Oil sight glass FCD Flow control device TTB Terminal box with temperature transmitter NP Nameplate NOTE Technical term In this instruction manual we consider that the term machine refers to the vacuum pump NOTE Illustrations In this instruction manual the illustrations may differ from the machine appearance ...

Page 5: ... machine By means of process control and or vacuum relief valves it must be made sure that the minimum allowed ultimate pressure will not be underrun The machine is suitable for continuous operation In order to avoid reverse rotation after switching off the machine is equipped with a non return valve NRV Note The non return valve NRV is no reliable means to prevent suction and shall not be used as...

Page 6: ...installed see Wiring Diagram Flow Control Device 2 5 Optional Accessories 2 5 1 Inlet Filter The inlet filter protects the machine against dust and other solids in the process gas The inlet filter is available with a paper or polyester cartridge The inlet filter protects the machine against dust and other solids in the process gas The inlet filter is available with a paper or polyester cartridge 3...

Page 7: ...machine indoors dry dust free and if possible in original packaging preferably at temperatures between 0 40 C 5 Installation WARNING Lack of oxygen regulation knowledge Risk of fire Installation commissioning and maintenance must only be carried out by qualified personnel who are informed about the applicable safety regulations and trained in the handling of oxygen Accident prevention regulations ...

Page 8: ... Technical Data 19 Make sure that the environmental conditions comply with the protection class of the motor and the electrical instruments Make sure that the installation space or location is vented such that sufficient cool ing of the machine is provided Make sure that cooling air inlets and outlets are not covered or obstructed and that the cooling air flow is not affected adversely in any othe...

Page 9: ...iciency Seek advice from your Busch representative 5 2 1 Suction Connection NOTICE Ingress of foreign objects or liquids Risk of damage to the machine If the inlet gas contains dust or other foreign solid particles Install a suitable filter 5 micron or less upstream from the machine Connection size s G3 Depending on the specific order other connection dimensions may apply 5 2 2 Discharge Connectio...

Page 10: ...ate oil Risk of premature failure Loss of efficiency Only use an oil type which has previously been approved and recommended by Busch 5 4 Electrical Connection DANGER Live wires Risk of electrical shock Electrical installation work must only be executed by qualified personnel Make sure that the power supply for the motor is compatible with the data on the nameplate of the motor The electrical inst...

Page 11: ...machine Operation in the wrong direction of rotation can destroy the machine in a short time Prior to start up ensure that the machine is operated in the right direction Determine the intended direction of rotation with the arrow stuck on or cast Jog the motor briefly If the rotation of the motor must be changed Switch any two of the motor phase wires Delta connection low voltage Star connection h...

Page 12: ... safety regulations and trained in the handling of oxygen Accident prevention regulations or methods must imperatively be complied with Seek further information European Industrial Gases Association EIGA www eiga eu EIGA SAG NL 79 04 Berufsgenossenschaft Rohstoffe und chemische Industrie BG RCI www bgrci de Merkblatt M 034 Sauerstoff NOTICE Lubricating a dry running machine compression chamber Ris...

Page 13: ...maintenance and troubleshooting work 7 Maintenance WARNING Lack of oxygen regulation knowledge Risk of fire Installation commissioning and maintenance must only be carried out by qualified personnel who are informed about the applicable safety regulations and trained in the handling of oxygen Accident prevention regulations or methods must imperatively be complied with Seek further information Eur...

Page 14: ...ke sure to have an authorisation from Busch to perform any maintenance tasks 7 1 Maintenance Schedule The maintenance intervals depend very much on the individual operating conditions The intervals given below are considered as starting values which should be shortened or extended as appropriate Particularly harsh applications or heavy duty operation such as high dust loads in the environment or i...

Page 15: ... the level does fall this indicates a leak and the machine requires repair Fill up if necessary see Oil Filling 10 7 3 Cleaning from Dust and Dirt SCH Mink BU 4 mm hex key Remove the front cover and untie the rolled up cable before removing side covers SCH Mink BU Clean the ventilation grilles and cooling fins 4 mm hex key ...

Page 16: ...nated with foreign ma terials which are dangerous to health Decontaminate the machine as much as possible and state the contamination status in a Declaration of Contamination Busch will only accept machines that come with a completely filled in and legally bind ing signed Declaration of Contamination form downloadable from www buschvacuum com 9 Decommissioning Shut down the machine and lock agains...

Page 17: ...the warranty WARNING Use of non Busch genuine spare parts Risk of fire Only use Busch spare parts approved by Busch and suitable for oxygen application If other parts are required Contact your Busch representative for the detailed spare parts list 11 Troubleshooting DANGER Live wires Risk of electrical shock Electrical installation work must only be executed by qualified personnel CAUTION Hot surf...

Page 18: ...The inlet filter cartridge op tional is partially clogged Replace the inlet filter cartridge Internal parts are worn or damaged Repair the machine con tact Busch The machine runs very noisily Worn coupling CPL Replace the coupling CPL Oil level too low Top up oil Defective bearings Repair the machine con tact Busch The machine runs too hot Insufficient cooling Remove dust and dirt from the machine...

Page 19: ...ion pressure 50Hz 60Hz dB A 75 79 Ambient temperature range C 0 40 Ambient pressure Atmospheric pressure Oil capacity l 1 2 Temperature transmitter Trip signal C 250 Flow control device Monitoring speed range Trip signal low Trip signal high min 1 1200 3600 Weight approx kg 472 13 Oil YLC 250 B Part number 0 5 L packaging 1 kg 0831 131 400 Part number 1 0 L packaging 2 kg 0831 108 878 Part number ...

Page 20: ...lowing designated standards that have been used to fulfil those provisions Standard Title of the Standard EN ISO 12100 2010 Safety of machinery Basic concepts general principles of design EN ISO 13857 2019 Safety of machinery Safety distances to prevent hazard zones being reached by the upper and lower limbs EN 1012 1 2010 EN 1012 2 1996 A1 2009 Compressors and vacuum pumps Safety requirements Par...

Page 21: ...Note ...

Page 22: ...Note ...

Page 23: ...Note ...

Page 24: ...o busch it Japan info busch co jp Korea busch busch co kr Malaysia busch busch com my Mexico info busch com mx Netherlands info busch nl New Zealand sales busch co nz Norway post busch no Peru info busch com pe Poland busch busch com pl Portugal busch busch pt Romania office buschromania ro Russia info busch ru Singapore sales busch com sg South Africa info busch co za Spain contacto buschiberica ...

Reviews: