Troubleshooting | 11
0870168572_MV0310B_-0001_IM_en_MD
27 / 32
11 Troubleshooting
DANGER
Live wires.
Risk of electrical shock.
• Electrical installation work must only be executed by qualified personnel.
CAUTION
Hot surface.
Risk of burns!
• Prior to any action requiring touching the machine, let the machine cool down first.
VRE
IS
CPL
Problem
Possible Cause
Remedy
The machine does not start. The variable-frequency
drive (VFD) is not supplied
with the correct voltage.
• Check the power supply.
The motor or the variable
frequency drive (VFD) is
defective.
• Replace the motor or the
variable-frequency drive
(VFD).
The coupling (CPL) is de-
fective.
• Replace the coupling
(CPL).
The machine does not
reach the usual pressure on
the suction connection.
The inlet screen (IS) is par-
tially clogged.
• Clean the inlet screen
(IS).
The vacuum relief valve
(VRE) is misadjusted or de-
fective.
• Replace the vacuum re-
lief valve (VRE)
The inlet filter cartridge (op-
tional) is partially clogged.
• Replace the inlet filter
cartridge.
Internal parts are worn or
damaged.
• Repair the machine (con-
tact Busch).
Summary of Contents for Mink MV 0310 B
Page 23: ...Maintenance 7 0870168572_MV0310B_ 0001_IM_en_MD 23 32 ...
Page 31: ...Note ...