13 | Electrical Data of Control Unit Terminals
28 / 32
0870221625_MV0040-0080D_-0000_IM_en_MD
13 Electrical Data of Control Unit Terminals
Terminal
Technical Information
20
Digital Out
Open collector max. 35 V / 50 mA
18
Analogue Out
0 … 10 V (max. 30 mA);
Short-circuit protected;
Resolution 0.1%; ac/-2.5%
16
Digital In 6
Positive or negative logic
Ri = min. 4 kΩ;
15 … 30 V = ‘1’
0 … 5 V = ‘0’
15
Digital In 5
14
Digital In 4
13
Digital Out Ground
Ground for digital output 1
5
Ground
Ground for reference and controls
(connected internally to frame earth through 2MΩ)
4
Analogue In 2
0 … +10 V (Ri = 200 kΩ);
4 … 20 mA (Ri = 250 Ω);)
Resolution 0.05%; ac/-1%;
Voltage or current (selectable with DIP-switch SW3)
10
Digital In 1
Positive or negative logic
Ri = min. 4 kΩ;
15 … 30 V = ‘1’
0 … 5 V = ‘0’
9
Digital In 2
8
Digital In 3
7
Digital Ground
Ground for digital inputs.
Connected to ground with DIP-switch SW1
6
24 V Out
24 V +/-10 %; max. voltage ripple <100 mVrms; max. 100 mA;
Short-circuit protected;
Can be used with an external power supply (with a current limiter or
fuse protected) to supply the control unit and fieldbus for backup pur-
posed.
Dimensioning: max. 1000 mA / control unit.
3
Ground
Ground for reference and controls
(connected internally to frame earth through 2MΩ)
2
Analogue In 1
0 … +10 V (Ri = 200 kΩ);
4 … 20 mA (Ri = 250 Ω);)
Resolution 0.05%; ac/-1%;
Voltage or current (selectable with DIP-switch SW3)
1
10 V Out
+10 V, +/-5 %; max. 10 mA
A
RS485
Not used
B
RS485
Not used