5 | Installation
12 / 36
Instruction Manual Supplement DOLPHIN VL Systems ATEX_EN_en
NOTICE
Use of the machine outside of the permitted installation conditions.
Risk of premature failure!
Loss of efficiency!
• Take care that the installation conditions are fully complied with.
• Make sure that the ambient conditions comply with the
.
• Make sure that the environmental conditions comply with the protection class of the
motor.
• Make sure that the installation space or location is vented such that sufficient cooling
of the machine is provided.
• Make sure that cooling air inlets and outlets of the motor fan are not covered or ob-
structed and that the cooling air flow is not affected adversely in any other way.
• Make sure that enough space remains for maintenance work.
• Make sure that the machine is placed or mounted horizontally on a flat surface.
• Make sure that the machine is connected to an operating and cooling liquid system to
• Make sure that all provided covers, guards, hoods, etc. are mounted.
If the machine is installed at an altitude greater than 1000 meters above sea level:
• Contact your Busch representative, the motor should be derated or the ambient
temperature limited.
If additional electrical components not included in scope of delivery should be added:
• Make sure that they have a better or equal ATEX classification than that of the
machine, see the ATEX marking on the nameplate (NP).
5.2 Connecting Lines / Pipes
• Remove all protective covers before installation.
• Make sure that the connection lines cause no stress on the machine‘s connection; if
necessary use flexible joints.
• Make sure that the line size of the connection lines over the entire length is at least as
large as the connections of the machine.
In case of long connection lines it is advisable to use larger line sizes in order to avoid a
loss of efficiency. Seek advice from your Busch representative.
NOTICE
Ingress of foreign objects.
Risk of damage to the machine!
If the inlet gas contains foreign solid particles:
• Install a suitable inlet screen (smaller than 0.1 mm mesh size) upstream of the ma-
chine.
Summary of Contents for DOLPHIN VL 0100 A
Page 34: ...Note...
Page 35: ...Note...