Technical Data | 12
Instruction Manual Supplement DOLPHIN VL Systems ATEX_EN_en
29 / 36
VL 0530 A
VL 0800 A
Pumping speed (50Hz / 60Hz)*
m³/h
440 / 556
722 / 867
Ultimate pressure (50Hz / 60Hz)*
hPa (mbar)
abs.
130 / 130
Maximum overpressure (50Hz / 60Hz)
bar(g)
0.3 / 0.3
Nominal motor rating IEC (50Hz / 60Hz)
kW
11.0 / 15.0
18.5 / 22.0
Nominal motor speed (50Hz / 60Hz)
min
-1
1450 / 1750
Permitted motor speed range
min
-1
1000 … 1780
(~34 … 60 Hz)
1000 … 1780
(~34 … 60 Hz)
Noise level (EN ISO 2151)
(50Hz / 60Hz)
dB(A)
≤
72 /
≤
73
≤
75 /
≤
76
Design pressure
bar(g)
0.5
Design temperature
°C
120
Max. allowable gas inlet temperature
°C
80
Ambient temperature range
°C
5 … 40
Relative humidity
at 30 °C
90%
Ambient pressure
Atmospheric pressure
Cooling liquid flow rate – plate heat ex-
changer
m
3
/h
1.89 / 2.92
2.58 / 4.3
Cooling liquid flow rate – shell and tube
heat exchanger
m
3
/h
3.06 / 11.58
8.52 / 8.22
Maximum cooling liquid pressure
bar(g)
10
Min. operating liquid density
kg/m
3
850
Max. operating liquid viscosity
cP
20
Instrument electrical supply
24 VDC
Weight – Once through (50Hz)
kg
510
591
Weight – Partial recovery (50Hz)
kg
517
599
Weight – Total recovery, plate heat ex-
changer (50Hz)
kg
556
639
Weight – Total recovery, shell and tube
heat exchanger (50Hz)
kg
584
667