Maintenance

CAUTION

Any dismantling of the vacuum pump that is beyond the scope of
what is described in this manual must be done by specially trained
Busch service personnel only.

CAUTION

During operation the surface of the vacuum pump can exceed tem-

peratures of 90°C.

Risk of burns!

Before starting maintenance work, make sure that the vacuum pump
has been fully switched off and that it cannot accidentally be switched
on again. Follow the procedure for stopping the pump in section
“ Stopping procedure for maintenance ” :

Switch off the vacuum pump

Switch off the main power supply

Put up the warning sign “ Maintenance in progress ” on or next to
the pump

CAUTION

During operation the oil temperature of the vacuum pump can
reach a value of 120°C !

Risk of burns !

After the completion of all maintenance work, follow the procedure
“Start-up procedure after maintenance” “ :

Remove the sign “ Maintenance in progress ”

Check the oil levels, top up with oil if necessary,

switch on the main supply

Make sure that the “Installation Prerequisites” are complied with

Switch on the vacuum pump

Maintenance Precautions

CAUTION

The following safety instructions are only relevant when dismantling
the magnetic drive system.

DANGER

Keep people wearing a pacemaker away from the influence of the
magnetic field!

Danger to life

DANGER

Label any room, where assembly or dismantling work on the ma-
gnetic coupling system is carried out or where parts of the magne-
tic coupling system are stored, with the danger sign :

“ No trespassing for persons with pacemaker ”

Do not place the dismantled magnetic coupling into the vicinity of
computers, data carriers and other electronic components.

Keep all magnetizable parts away from the magnetic coupling.

CAUTION

The powerful magnetic field can influence the functioning and ope-
rational safety of electrical and electronical units.

CAUTION

Improper or incorrect maintenance work on the vacuum pump will

put the safety of operation at risk.

Risk of explosion !

It is strongly advised that any dismantling of the vacuum pump that
goes beyond the scope of what is described in this manual should
be done by specially trained Busch service staff only.

Fitting the magnetic coupling

Step 1

Carry out an inspection by measuring the length of the spacer (2).
This measurement must be 31,5 mm.

Fit the spacer (2), and position the shaft key (5) as well as the inner
part of the magnetic coupling (1) onto the rotor shaft.

Measure the distance between the face of the magnetic coupling's
inner rotor (1) and the supporting face of the cover (4). This value
(x) must be 99,5 mm.

Use the washer (3) and the screw (6) to fix axially.

Step 2

Fit the adapter flange (7) with its o-ring (8) into the housing (4)
using the two fixing screws (11)

Screw and glue the two guiding rods (10) onto the adapter flange
(7).

Fit the ceramic bell housing (9) of the coupling with its o-ring (15)
onto the adapter flange (7).

COBRA Vacuum Pump with Magnetic Coupling

Maintenance

0870549497 (EN)

Page 5

X

X= 99,5 mm

217 mm

4

5

2

1

3

6

Summary of Contents for COBRA NC 400 B

Page 1: ...ion and Maintenance manual COBRA Vacuum Pump with Magnetic Coupling Screw Vacuum Pumps COBRA NC 400 B Ateliers Busch S A Zone industrielle 2906 Chevenez Switzerland 0870549497 081209 Original instruct...

Page 2: ...la tion and operation of the COBRA vacuum pump equipped with ma gnetic coupling Introduction Congratulations on the purchase of your Busch vacuum pump Whilst always responding to customers requirement...

Page 3: ...the pump as well as influences on operating conditions maintenance troubleshooting and overhaul of the vacuum pump The vacuum pump is intended for industrial use It may only be opera ted by qualified...

Page 4: ...rtified category 2G i o pumps the temperature class must be watched by measuring the surface temperature of the cera mic bell using a PT100 temperature sensor installed on the pump WARNING Minimum obl...

Page 5: ...tem is carried out or where parts of the magne tic coupling system are stored with the danger sign No trespassing for persons with pacemaker Do not place the dismantled magnetic coupling into the vici...

Page 6: ...ure to keep good control over the axial forces Risk of squashed fingers Tighten the screws 432 Dismantling the motor the lanterne the exterior coupling CAUTION Always make sure that the vacuum pump is...

Page 7: ...s with the help of the two guiding rods These help to com pensate radial forces CAUTION While mounting this unit control the axial force Risk of squashing fingers due to the effect of magnetism Inacti...

Page 8: ...Note...

Page 9: ...e within Certain Voltage Limits so called Low Voltage 2006 95 EC Electromagnetic Compatibility 2004 108 EC have been designed and manufactured to the following specifications Standard Title of the Sta...

Page 10: ...Note...

Page 11: ...Note...

Page 12: ...ss Centre Kilbarrack Dublin 5 Tel 00353 1 832 1466 Fax 00353 1 832 1470 Israel Busch Israel Ltd 1 Mevo Sivan Street Qiryat Gat 82022 Israel Tel 972 0 8 6810485 Fax 972 0 8 6810486 Italy Busch Italia S...

Reviews: