Troubleshooting | 11
0870573045_NC1500B_VR_A0002_IM_en
29 / 32
The machine runs too hot.
Insufficient cooling.
• Make sure to comply with
the cooling liquid require-
ments, see
.
Ambient temperature too
high.
• Observe the permitted
ambient temperature, see
Temperature of the process
gases at the inlet too high.
• Observe the permitted
gas inlet temperature, see
Oil level too low.
• Top up oil.
The oil is black.
Oil change intervals are too
long.
• Drain the oil and fill in
.
The machine runs too hot.
• See problem "The ma-
chine runs too hot".
For the solution of problems not mentioned in the troubleshooting chart contact your
Busch representative.