10 | Decommissioning
34 | 44
Instruction Manual COBRA NX 0950 A WCV_EN_en
10
Decommissioning
DANGER
Live wires.
Risk of electrical shock.
●
Electrical installation work must only be executed by qualified personnel.
CAUTION
Hot surface.
Risk of burns!
●
Prior to any action requiring touching the machine, let the machine cool down first.
●
Shut down the machine and lock against inadvertent start up.
●
Disconnect the power supply.
●
Turn off the water supply.
If the machine is equipped with a barrier gas system:
●
Close the barrier gas supply.
●
Vent the connected lines to atmospheric pressure.
●
Drain the cooling water from the two cooling water drain plugs (CWD).
●
Disconnect all connections.
If the machine is going to be stored:
●
11].
10.1
Dismantling and Disposal
●
Drain and collect the oil.
●
Make sure that no oil drips onto the floor.
●
Separate special waste from the machine.
●
Dispose of special waste in compliance with applicable regulations.
●
Dispose of the machine as scrap metal.