5 | Installation
32 / 60
0870203597_NC0100-0300B_WCV_Ex_-0001_IM_en
NOTICE
Incorrect direction of rotation.
Risk of damage to the machine!
• Operation in the wrong direction of rotation can destroy the machine in a short time!
Prior to start-up, ensure that the machine is operated in the right direction.
The intended rotation direction of the motor is defined by the illustration below:
IN
• Jog the motor briefly.
• Watch the fan wheel of the motor and determine the direction of rotation just before
the fan wheel stops.
If the rotation of the motor must be changed:
• Switch any two of the motor phase wires.
5.8.2 Wiring Diagram Solenoid Valve
2 (-)
1 (+)
PE
Part no.
Supplier reference
P&ID posi-
tion
Specifications
Maintenance
procedure
0654 000 092 Parker Lucifer
495905 C2
MV2 ;
MV3 ;
MV4 ; MV5
DN 3
with seal in FFKM
Ex db mb IIC T4
U
i
= 24 VDC
0654 538 544 Parker Lucifer
495910 N7
MV2 ;
MV3 ; MV5
DN 1.5
with seal in PUR
Ex ia IIC T4
U
i
= 24 VDC
0654 532 461 Bürkert
Type 262 (pneumatic)
Type 6014 C (electric)
MV2 ;
MV3 ;
MV5 ; MV7
DN 12
with seal in PTFE
pneumatic 3 ... 6 bar
Ex ia IIC T5
U
i
= 24 VDC
0654 547 028 Parker Lucifer
495905 F4
MV2 ;
MV3 ; MV5
DN 3
with seal in FFKM
Ex dm mb IIC T4
U
i
= 230 VAC
0654 552 169 Parker Lucifer
495910 N7
MV4
DN 1.5
with seal in Rubis
Ex ia IIC T4
U
i
= 24 VDC
0654 536 403 Bürkert
Typ 6014
MV4
DN 0.9
with seal in FKM
Ex ia IIC T6
U
i
= 24 VDC
0654 518 062 Parker Lucifer
495905 C2
MV7
DN 12
with seal in FKM
Ex db mb IIC T4
U
i
= 24 VDC
0654 545 633 Parker Lucifer
483580.01
MV7
DN 15
with seal in PTFE
pneumatic 3.5 ... 10 bar
Ex ia IIC T6
U
i
= 24 VDC
0654 518 061 Parker Lucifer
495905 F4
MV7
DN 12
with seal in FKM
Ex dm mb IIC T4
U
i
= 230 VAC