12
Installation of the system
6. Connections on the electronics box
The additional components of the BURY CP 1100 are connected to the electronics box.
The following connections are provided:
Connection options:
1 Power supply
2 External loudspeaker
3 Microphone
4 BURY CP 1100
1 - Power supply
The power supply of the BURY CP 1100 is established via a 4-core ca-
ble. Connect the black (clamp 31 – minus), the red (clamp 30 – steady
plus) and the blue cable (clamp 15 – ignition plus) to the power supply
of your radio (where required via the cigarette lighter or the fuse box).
After connection to the counterpart, the yellow cable provides for radio
muting during a phone conversation. Please connect the white Molex
connector with connection 1.
Note:
Do not connect your device to the power supply or switch
X
it on until instructed to do so in the installation instruc-
tions.
Attention:
If you also connect the blue cable to clamp 30 (steady
X
positive), the BURY CP 1100 will be permanently supplied
with power. If the vehicle is not running for a longer period,
this could lead to a discharge of the car battery.
If you deviate from the specified connection descrip-
X
tions it may be the case that certain functions on the BURY
CP 1100 (e.g. the on-call duty) will not function correctly.