4.2.4 LED Module Replacement
WARNING: Make sure power is removed before performing any maintenance.
Refer to the circled numbers in the illustration:
•
Remove the three screws and the top lid.
•
Disconnect the wires for the
LED module from the terminal
block next to the cooling fan in
the
center.
•
Loosen the two
pivot crews.
•
Remove module assembly
•
Remove LED module screws
and remove bad module. Re-
move LED Cable and set aside.
•
Place new LED board and
route cable thru heatsink, if no
cable provide, used cable set
aside. Replace LED board
screws
•
Reverse bullet points 3, 2, 1.
4.2.2 Ceiling Versions
The fuse holder is located within the terminal block To access the ceiling mount terminal
block,
the ceiling dome must be removed. This is done by loosening the two set screws on the locking ring
(indicated by the arrow). Replace the fuse and re
-
assemble in the opposite order.
4.2.3 Wall Versions
The fuse holder is located within the terminal block. To access the wall mount terminal block, the
wall mount cover must be removed. This is done by loosening the four screws that secure the cover
on mount (indicated by the arrow). Replace the fuse and re
-