Troubleshooting
14
14.6.2
Alde heater/boiler
Z
If a fault occurs in the system, the cause is shown on the display.
Fault
Cause
Remedy
Heater does not ignite
with gas operation
Lack of gas
Open regulator tap and
gas isolator tap
Connect a full gas bottle
Heater does not ignite
Battery voltage too low
Charge battery. If the
battery voltage rises
above 11 V, the heater is
switched on
automatically
Heater does not ignite at
230 V electrical operation
No 230 V power supply
Switch on the 230 V
automatic circuit breaker
Connect the 230 V power
supply
Heater switches off
Overheating
Allow the heater to cool.
To reset the display,
interrupt the 12 V power
supply to the heater and
switch it back on again
Heater running, but no
heat at the convectors
Circulating pump does
not work
Switch on room
thermostat
Contact customer service
Heater and circulating
pump running, but no
heat at the convectors
Air in the heating system
Bleed hot-water heater
Summary of Contents for Ixeo Time IT 590
Page 2: ...T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Instruction manual ...
Page 10: ...10 T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Introduction 1 ...
Page 56: ...56 T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Pitching the motorhome 5 ...
Page 118: ...118 T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Gas system 7 ...
Page 184: ...184 T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Appliances 9 ...
Page 248: ...248 T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Special equipment 15 ...
Page 262: ...262 T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Helpful notes 17 ...