Burster 9186-V Series User Manual Download Page 7

 

 

 Typ 9186-VX1XX

 

 

www.burster.de 

Display and keyboard 

 

 

 

 

 

 

 

UP 

SHIFT 

DATA 

ENTER 

 

 

 

RUN 

MODE  

PRO 

MODE  

4 red digit Display 

Shows value according configuration. 

Shows steps and data during configuration. 

Keyboard 

 

 

Setpoint 1 LED 

It iluminates when Setpoint 1 turns active. 

It iluminates when Setpoint 1 turns active. 

UP key 

Display TARE. 
TARE RESET (when pressing more than 3s). 

Shows Setpoints value. 
Increases value of active digit. 

SHIFT key 

Displays maximum and minimum stored values. 

After 3s of pressing, sets maximum and/or minimum 
memorized value to current display value. 

Shifts active digit to the next right digit. 
Shows sequentially menu options. 

DATA/ENTER key 

Changes to PRO mode. 

Validates selected data and parameters. 

Moves one step forward in configuration menu. 
Changes to RUN mode. 

Setpoint 2 LED 

It iluminates when Setpoint 2 turns active. 

It iluminates when Setpoint 2 turns active. 

Free space for units label 

 

 

There  are  two  main  function  modes: 

RUN 

and 

PRO

PRO

  mode  is  when 

configuration  menu  is  entered  to 
programm  the  indicator,  whereas  

RUN

  is  the  normal  mode  in  which 

display  shows  the  reading  according 
to  configuration  and  input  signal 

value. 
 

The  table  below  summarizes  display 
parts  description  and  LEDs  and 

keyboard function. 

Installing and connecting recommendations 

WARNING: If this instrument is not installed and used in accordance with this instructions, 

the protection provided by it against hazards may be impaired. 

To  meet  the  requirements  of  EN  61010-1  standard,  where  the  unit  is  permanently  connected  to  main 

supply,  its  is  obligatory  to  install  a  circuit  breaking  device  easy  reachable  to  the  operator  and  clearly 
marked as the disconnecting device. 
 

To guarantee electromagnetic compatibility, the following guidelines should be kept in mind: 

 

 

Power supply wires should be separatedly routed from signal wires and 

never  runned 

in the same 

conduit. 

 

Use shielded cable for signal wiring. 

 

Cables section should be 

 

0.25 mm²

 

Before  connecting  signal  wires,  signal  type  and  input  range  should  be  verified  to  be  within  the  right 
limits. 

This instrument coforms with the following community directives: EMC 2004/108/CE and LVD 2006/95/CE. 
Refer to the instructions in this manual to preserve safety protections. 

 

Summary of Contents for 9186-V Series

Page 1: ...Typ 9186 VX1XX www burster de USER MANUAL DIGITAL INDICATOR FOR LOAD CELL INPUT Typ 9186 VX1XX...

Page 2: ...figuration 10 DISPLAY CONFIGURATION Display programming 12 Display scaling 12 mV input 13 SETPOINTS CONFIGURATION Setpoints configuration 14 AVAILABLE KEYBOARD FUNCTIONS TARE MAX MIN and RESET functio...

Page 3: ...ER General safety considerations Symbols identification WARNING Risk of electric shock Instrument protected by double isolation or reinforced isolation All instructions and guidelines for the installa...

Page 4: ...brations regularly in accordance to operation criteria in each application Instrument calibration and or adjustment should be performed only by an accredited laboratory or directly by the manufacturer...

Page 5: ...N 2 kV L N to Earth 1 kV Signal lines to Earth EN 61000 4 6 RF conducted interference Criterion A 3 Vrms EN 61000 4 11 Voltage dips 0 V during 1 cycle Criterion B 40 V during 10 12 cycles Criterion C...

Page 6: ...mum range of 1999 to 9999 which allows a better reading at longer distance Minus LED sign is integrated in the most significative digit They have three frontal keys to interact with internal software...

Page 7: ...nu is entered to programm the indicator whereas RUN is the normal mode in which display shows the reading according to configuration and input signal value The table below summarizes display parts des...

Page 8: ...ls Once all connections are done plug connectors to the instrument Rear connectors location Key tool for cable insertion Load cell input signal wiring diagrams mV CN2 1 IN COMMON 2 IN 300mV 30mV 3 N C...

Page 9: ...ween pin 4 and pin 5 of CN2 input connector must be able to provide a current of 4mA and withstand up to 40V In both cases remote TARE is activated when contact is closed less than 3 seconds Remote TA...

Page 10: ...tion menu The instrument provides 3 keys for progressing through the menus and submenus and for data introducing modifying ENTER Vertical displacement Validates data UP Increases active digit value SH...

Page 11: ...burster de 11 EXCITATION LEVEL Configurable value E 5 5V DC E 10 10V DC Once input range is selected the routine goes to configure excitation 5V and 10V are available In both cases load current limit...

Page 12: ...ff frequency Fc which allows the instrument to smooth out undesirable display reading fluctuations Display scaling is necessary when adapting display reading to a particular engineering unit Display r...

Page 13: ...isplay value indication 0000 Value entering in counts within available model display range FiLt 0 SCAL InP1 tEAC 0000 dSP1 0000 00 00 InP2 0000 dSP2 0000 For both display scaling SCAL and tEAC methods...

Page 14: ...0 to 99 9s HyS Hysteresis in counts within available model display range 00 00 SETPOINTS CONFIGURATION If 2RE output option card is uninstalled the instrument keeps setpoints last configuration in me...

Page 15: ...limit value defined by the working range Otherwise overflow indication OuE will be displayed Stored tare value remains in memory although power supply is removed This device detects and stores in memo...

Page 16: ...ult this code is 0000 Finally press ENTER to begin with lock out level configuration If entered security code is wrong the instrument will go back to RUN mode 3s To access this menu from RUN mode pres...

Page 17: ...ers a selective or total configuration lock out is available By default the unit is delivered unlocked giving access to all programming levels Once in this menu the first option will be to choose betw...

Page 18: ...IFT key lock out for MAX MIN function is configurable in the same way as previous configurations When lock out is enabled selecting yES it is not possible to visualize maximum or minimum values by pre...

Page 19: ...ch case just when setpoint SET is reached by display Hysteresis delay for OUT1 HI mode and for OUT2 LO mode 2RE output option allows TYP 9186 VX1XX models to perform control operations and limit value...

Page 20: ...slide properly without much effort through rear case internal guides Each output card is supplied with an adhesive label that indicates wiring connections To help identifying terminals this label shou...

Page 21: ...VERSION OPTION 9186 V31XX Connectors location and description 8 pin assignment for terminal implementation TARE DMS Digital Out function 9186 V31XX with Load Cell DMS wiring diagram Signal Shield Exci...

Page 22: ...Through frontal key ENVIRONMENTAL CONDITIONS Operating temperature 10 C 60 C Storage temperature 25 C 85 C Relative humidity non condensing 95 40 C Maximum altitude 2000m Frontal protection degree IP...

Page 23: ...template for the annotation of configured parameters in your instrument for later consulting or data recover INPUT TYPE RANGE DISPLAY CONFIG MODE INPUT 1 DISPLAY 1 INPUT 2 DISPLAY 2 FILTER 0 8 SETPOIN...

Page 24: ...9186 VX1XX www burster de 24 burster pr zisionsmesstechnik gmbh co kg Talstr 1 5 D 76593 Gernsbach Germany Tel 49 07224 6450 Fax 49 07224 64588 Email info burster de web www burster de 28 10 2013 3072...

Reviews: