Page 4
Torque Sensor
Model 8627, 8628, 8632
References in this text
1.6
Warning notes; Page 8
Attention must be paid to the accident prevention regulations of
the trade associations.
During operation the safety precautions must be serviceable.
4.
Mechanical assembly; Page 11
Caution: During the assembly inadmissibly large forces may not
act on the sensor or the coupling. At small torques (< 20 Nm) con-
nect the sensor electrically during the assembly and observe the
signal, the measurement signal may not exceed the limit values.
During the assembly, the sensor must be supported to protect it
from falling down.
Caution at permutation of drive side and measuring side.
4.1
Sensors up to 15 Nm; Page 11
Sensor with nominal torques up to 15 Nm are very sensitive re-
garding overload; therefore treat the sensors with great caution.
6.1
Engaging; Page 15
The warm-up period of the torque sensor is approx. 5 min.
6.4.2
Natural resonance; Page 16
Operation of the device in natural resonance can lead to permanent
damages.