15
For mixer cycle:
Mixer settings 1
→
Mixer
room thermostat
= 0
In
case
of
connected
room
panel
ecoSTER200
set
additionally
room
temperature factor
= 0
Guidelines for correct heating curve settings:
Floor heating 0,2 – 0,6
Radiator heating 1,0 – 1,6
Buffer 1,8 - 4
Pic. 9 Heating curves.
Tips for choosing proper heating curve:
If by falling outer temperature room
temperature is increasing, then value of
chosen heating curve is too big,
If by decreasing outer temperature, room
temperature is also decreasing, then value of
chosen heating curve is too low,
If by frosty weather room temperature is
appropriate and in warmer time is too low –
it is recommended to increase parameter
Heating curve parallel shift
and then choose
lower heating curve,
If by frosty weather room temperature is too
low and in warmer time too high – it is
recommended to reduce
Parameter heating
curve parallel shift
and choose higher heating
curve.
Buildings which are poorly insulated require
setting heating curve with higher values, and
for better isolated buildings heating curve
will have lower value.
Preset temperature, counted according to
heating curve can be decreased or increased
by controller when it goes beyond scope of
limits of temperatures for given cycle.
8.17.
NIGHT
REDUCTION
SETTINGS
DESCRIPTION
In the controller it is possible to set time
periods of silo temperature reduction,
heating cycles, hot water silo, and circular
pump.
Time periods allow setting temperature
reduction in given time period – i.e. at night
or when user leaves the heated room.
Thanks to it preset temperature can be
reduced automatically, without loss of
heating
comfort
by
reducing
fuel
consumption.
To activate time periods use parameter
Night
reduction
for given cycle and activate it.
Night reductions can be defined separately in
working days, Saturdays and Sundays.
Pic. 10 Window of time periods choosing.
It is needed to set the beginning and the end
of given time period and value with which
the preset temperature will be reduced.
Pic. 11 Time periods edition.
Below sample preset night temperature
reduction is presented.