background image

© 2008 U.S. Boiler Company, Inc. - Lancaster, PA

Phone: 1-888-432-8887

www.burnham.com

Printed in the U.S.A.

Form No.  PL81401301000-9/08-10M

Ratings

Specifications

Model 

Number

Burner Capacity (GPH)

DOE  

Heating Capacity (MBH)

I=B=R 

Water Ratings

            AFUE%

MPO84

.60

74

64

87

MPO115

.80

98

85

87

MPO147

1.05

129

112

87

MPO189

1.35

167

145

87

MPO231

1.65

203

177

87

Model

Number

Dimensions (inches)

Water

Content (gal.)

Natural Vent

Approximate 

Shipping Weight (lbs.)

Direct Vent

Approximate 

Shipping Weight (lbs.)

‘A’

‘B’

‘C’

MPO84

16-5/8

24

5

7.70

475

N/A

MPO115

16-5/8

24

5

7.70

475

N/A

MPO147

22-5/8

24

6

11.08

567

579

MPO189

28-5/8

30

6

14.46

659

692

MPO231

34-5/8

30

7

17.84

751

807

MPO Direct Vent Kit

Model

Number

Vent Connector 

Diameter (inches)

Optional Starter “T” 

Depth ‘D’ (Inches)

MPO147

5

14

MPO189

5

14.5

MPO231

6

14.5

FRONT SERVICE 

CLEARANCE 

(FLUEWAY CLEANING) 

‘C’ 

DIA. 

COLLAR 

‘B’

 MIN. 

TOP VIEW 

FRONT VIEW 

SIDE VIEW 

BACK VIEW 

‘A’ 

5

8

22 

“ 

33” 

3

8

21 

“ 

Optional
Stainless Steel 
DV Starter “T”

‘D’

Summary of Contents for MPO Series

Page 1: ... Boiler Five Sizes Available 0 60 1 65 gallons Direct Vent Option Kit Three Sizes Available 1 05 1 65 gallons Easy Installation and Servicing with Reversible Swing Door and no Target Wall or Blanket Required Multiple Burner Options Oil Fired High Efficiency 3 Pass Water Boilers ...

Page 2: ...fles rear cleanout access plates and ample flueway clearance for easy cleaning Multiple Burner Options Burnham offers the flexibility of multiple burner choices for the MPO boiler A selection of burners from industry leading manufacturers is available for all MPO sizes MPO Direct Vent Kit No chimney The MPO DV Direct Vent Option Kit is the perfect solution The venting kit includes a stainless stee...

Page 3: ...ywell L7248 electronic aquastat includes digital display and interface capability to provide diagnostic information Reversible Swing Away Burner Door Offers easy access to combustion chamber for cleaning Large Geometric Combustion Chamber Without a target wall or blanket increases heat transfer and reduces costs on repair parts 3 Pass Cast Iron Heat Exchanger Flue gases are recirculated through th...

Page 4: ...s Water Content gal Natural Vent Approximate Shipping Weight lbs Direct Vent Approximate Shipping Weight lbs A B C MPO84 16 5 8 24 5 7 70 475 N A MPO115 16 5 8 24 5 7 70 475 N A MPO147 22 5 8 24 6 11 08 567 579 MPO189 28 5 8 30 6 14 46 659 692 MPO231 34 5 8 30 7 17 84 751 807 MPO Direct Vent Kit Model Number Vent Connector Diameter inches Optional Starter T Depth D Inches MPO147 5 14 MPO189 5 14 5...