background image

Figure 2: Lighting Instructions

Alpine™ Series Lighting and Operating Instructions

Summary of Contents for Alpine Series

Page 1: ...nd service must be performed by a qualified installer service agency or the gas supplier AVERTISSEMENT Assurez vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d incendie ou d explosion ou pour éviter tout dommage matériel toute blessure ou la mort Ne pas entreposer ni utiliser d essence ni d autres vapeurs ou liquides inflam mables dans le voisinage...

Page 2: ...DANGER There are no user serviceable parts on this boiler Attempts to service this boiler by someone other than a qualified gas service technician could void the warranty cause property damage personal injury or loss of life CAUTION Should overheating occur or the gas supply fail to shut off do not turn off or disconnect the electrical supply to the pump Instead shut off the gas supply at a locati...

Page 3: ...ts Heating system water Leaks Carbon soot in or near the burner compartment area Make sure that the condensate drain system is unobstructed and leak tight CAUTION The Alpine ALP has a heat exchanger made from a special stainless steel alloy which can be severely damaged by frequent additions of water or by the addition of boiler water additives which are not designed for use with stainless steel b...

Page 4: ... Figure 1 Control Locations shown with optional concentric vent collar ...

Page 5: ... Figure 2 Lighting Instructions Alpine Series Lighting and Operating Instructions ...

Page 6: ...t 5 All Concentric internal Vent pipe joints must be secure gas tight and watertight 6 Condensate drain must be free of obstruction and allow condensate to flow freely If corrective action is required contact your installer or qualified service agency C Inspect burner Flames Monthly 1 Remove lower front door assembly 2 Adjust thermostat to the highest setting to initiate boiler firing 3 View burne...

Page 7: ...o the normal setting to stop boiler firing D Schedule Inspection by Your Installer or Qualified Service Agency Annually or at Beginning of Heating Season For continued safe operation either your installer or a qualified service agency must provide a more detailed inspection of burner heat exchanger controls and vent system and provide maintenance as specified in Installation Operating and Service ...

Page 8: ...y service or repair work involving RCF without wearing the following protective gear 1 A National Institute for Occupational Safety and Health NIOSH approved respirator 2 Long sleeved loose fitting clothing 3 Gloves 4 Eye Protection Take steps to assure adequate ventilation Wash all exposed body areas gently with soap and water after contact Wash work clothes separately from other laundry and rins...

Reviews: