4
General Information
General Information
Introduction
We extend a warm welcome from all of us at
Burntech
Fireplace Solutions
, proud manufacturers of
Burntech
Modular Masonry
Fireplaces.
Before Beginning the Installation
Read these instructions carefully before beginning the
installation of this Vent-Free
fi
replace. Also read the gas
log appliance manufacturer’s literature regarding sizing and
suitability for installation into this Enclosure prior to installation.
Statement of Intended Use:
The
Burntech
Vent-Free Universal Masonry Fireplace is a
modular refractory masonry unit designed for
fi
eld assembly.
The
fi
rebox is constructed using pre-cast, interlocking
refractory blocks. The blocks are then secured to each other
using Mortar. The system includes all parts necessary for the
assembly of a complete masonry vent-free decorative gas log
enclosure.
In addition to the basic enclosure, a standard
1-1/8” thick, high temperature refractory brick is
required to line the interior of the
fi
rebox.
These
fi
replaces are not intended to serve as
a primary heat source, rather, the
fi
replace was
expressly created as a supplemental source of
heat.
The
Burntech
Vent Free Fireplace
is Designed
for Use Only with any Vent free decorative gas
log sets meeting standard ANSI Z21.11.2
Vent free decorative gas log sets meeting
standard ANSI Z21.11.2, are supplied by others
and are limited to any listed vent-free gas-
fi
red
log sets with heat input ratings up to 40,000
Btu/hr.
WARNING:
Any application other than the
“Intended Use” as stated above is in violation
of the manufacturer’s instructions and is hereby
prohibited. Such violation may cause immediate
hazard, property damage or loss of life and will
void all liabilities to the manufacturer and will
void all warranties explicit or implied.
Product Overview
Burntech
fi
replaces
are designed as Factory Built - Field
Assembled Fireplaces to be installed on both combustible
and non-combustible
fl
oor systems. They have been
extensively tested to perform with excellent results in this
environment.
Attention: Be advised that all the illustrations in this manual
are for general reference only. They are not drawn to scale.
Actual design elements will vary from case to case. Pay
attention to speci
fi
ed minimum clearances as they relate to
combustible materials.
SECTION A-A
W1
W3
W2
23 1/8"
28"
38 3/4"
46 3/4"
7 1/8"
21"
4 1/2"
32 5/8"
A
A
Figure 2
Model
W1
W2
W3
OFS/TFS
39VF 43”
39”
29-1/4”
OFS/TFS
44VF 48”
44”
34-1/4”
OFS/TFS
49VF 53”
49”
39-1/4”
OUTSIDE AIR ACCESS
Please call us with any installation questions or concerns at
(818)564-4253, We are here to help.