BURNTECH MODULAR FIREPLACE START UP CURING INSTRUCTIONS:
Burntech Fireplace’s require a specific curing process prior to normal useage. Doing so will
help to minimize shrinkage cracks in the mortar and in the fireplace components. Please
follow the curing process as described below prior to normal use of your Burntech
Fireplace.
Please refer to your installation manual for important information regarding
First Lighting
- After construction is completed, all elements of the fireplace must be
completely dry. This means that the unit must stand
without
any firing for a
minimum
of 28 days
.
Light your Vent Free gas logs with a flame approximately 3-4" high and keep lit
continuous
for one hour.
Wait a minimum of 24 hours until second lighting.
Second Lighting
-
Light your Vent Free gas logs with a flame approximately 4-6" high and
keep lit continuous for 2 hours. Wait a minimum of 24 hours until the third lighting.
Third
Lighting
–
Light your Vent Free gas logs with a flame approximately 6-8" high and keep
lit continuous for 2 hours. Wait a minimum of 24 hours until regular usage.Y
FOR ADDITIONAL COPIES OF THIS SHEET PLEASE VIST OUR WEBSITE
AT WWW.BURNTECH.COM
ATTENTION OWNER: THIS VENT FREE FIREPLACE IS DESIGNED FOR
USE WITH VENT-FREE GAS LOGS ONLY. NEVER BURN WOOD IN THIS
FIREPLACE AS IT DOES NOT HAVE A CHIMNEY FOR VENTILATION.
DOING SO CAN RESULT IN SERIOUS INJURY OR DEATH. PLEASE
REFER TO YOUR INSTALLATION MANUAL FOR IMPORTANT SAFETY
WARNINGS AND INFORMATION REGARDING SAFE AND EFFICIENT
OPERATION. IF YOU DID NOT RECIEVE A COPY OF YOUR
INSTALLATION MANUAL, ONE MAY BE OBTAINED FOR FREE FROM
OUR WEBSITE http://burntech.com/downloads-manuals.htm OR BY
CALLING US AT (818)564-4253.
You may now enjoy your Burntech fireplace!