Page 25
5. S
ERVICING
I
NSTRUCTIONS
5.1.
General Requirements
All repairs and servicing must be carried out by a qualified registered gas installer (e.g.
member of Gas Safe in GB) in accordance with the current Gas Safety (Installation and Use)
Regulations and these instructions.
Before any servicing is carried out ensure that the gas and electrical supply / transformer is
unplugged.
Always check for gas soundness after dismantling or exchange procedures.
On completion of the servicing, a spillage test must be carried out.
5.2.
Servicing Instructions
1. Remove the glass panel as described in the installation section and place it in a safe
place.
2. Carefully remove the two loose pegged coals from the top of the fuel bed. Carefully
remove the fuel bed moulding. Lift out the front and rear ceramics. Also remove the three
ceramic fibre lining boards. Any debris/dust or soot can be brushed off using a soft brush.
3. Turn off the gas supply at the isolator fitting. Disconnect the gas supply. Remove one of
the nuts in the slider control linkage and disconnect the linkage from the burner chassis at
actuating lever on front of gas burner. Remove the two screws at the rear and the two
screws at the front securing the burner chassis and gently lift it out of the appliance. Clean
the burner slot with a brush.
4. Check that the electrode sparks across the gap when the slider lever is pushed to the left.
5. Use a vacuum cleaner to remove any fluff or lint on the base of the combustion chamber.
6. Undo the two securing screws holding the fan shroud to the rear of the firebox and lift
clear. Clean the circulation fan with the vacuum cleaner and check the foam strip around
the end flanges is in good condition. Replace if necessary.
7. Replace the fan in position ensuring that the motor does not touch the side of the
appliance.
8. Replace the fan shroud and secure with the two screws previously removed.
9. Loosen the cable fixing clamp and slide the appliance forward.
10. Inspect and clean the flue as necessary.
11. Replace the appliance and tighten the fixing cable.
12. Refit the burner chassis and secure in place using the previously removed screws. Re-
connect the gas supply, turn on at the isolator fitting and check for leaks. Reconnect the
slider control linkage.
13. Replace the lining boards.
14. Replace the front and rear ceramics and replace the moulded fuel bed and loose coals as
described in the appropriate fuel bed layout sections 3.9.5
15. Refit the glass panel and secure in place using the clamp and self tapping screws
previously removed. Note; No.6 self tapping screws have been used from new, if a screw
strips its thread replace with a No.8 sized screw.
16. Light the appliance and after letting it warm carry out spillage test as detailed in the
installation section
17. Replace louvre, trim and fret.
Summary of Contents for Surefire FCC 16
Page 17: ...Page 15 4 3 General Dimensions...
Page 22: ...Page 20...