Locate  thermostat  bulb  in  a  cool  place  away  from  the  appliance  and  preferably 
outside of any inglenooks, to ensure it is sensing room air temperature. 

 

 

Run appliance for 15 minutes, ensuring burner flames settle evenly. 

 

 

A  combustion  analysis  check  should  then  be  carried  out.  Using  an  analyser  to 
BS7927, first zero the equipment and sample the entire width of the combustion 
product  outlet.

  Ratio  of  CO/CO2  should  be  less  than  0.002  within  30  minutes. 

(20ppm CO per 1% CO2)  A reading of CO in the room centre should give a rise of 

less  than  9ppm

  over  ambient,  peak  reading.  The  catalyst  is  unlikely  to  need 

replacement  during  the  life  of  the  appliance  but  if  the  combustion  is  suspect, 
disconnect  the  appliance  and  contact  the  manufacturer.  See  the  additional 
information on testing. 

 

 

11.

 

PARTS LIST 

 

Part 

Part No 

 

Front Ceramic Coal  

COA4241F 

 

Rear Ceramic Coal 

COA4241B 

 

Oxypilot NG 

Check if SIT or Seagas 

 

Oxypilot LPG 

Check if SIT or Seagas 

 

Glass 

GLA4140 

 

Grill 

GRI4240 

 

90mm Freestanding Spacer 

SPACERKIT 

 

Remote Valve (Mertik) 

VAL1921 

 

Remote Handset & Receiver 

VAL1924 

 

Trim Backer 

TRI4140 

 

60mm INFILL SPACER 

INF0140 

 

Pebble Set 

PEB4237F&B 

 

 

USE ONLY GENUINE REPLACEMENT PARTS. 

 

Parts ordered from our factory will normally take 5 – 7 working days to be delivered. 

An ‘Express service’ is available upon request.

 

 

Due  to  our  policy  of  continual  improvement  and  development  the  exact  accuracy  of 
descriptions and illustrations cannot be guaranteed. 

 

Burley Appliances are the only company to bench run and thoroughly test every single Flueless 
gas fire it produces. Burley is in the unique position of knowing that every appliance leaves the 
factory in perfect working order. 

 

 

 

 
 

Summary of Contents for EMPATHY

Page 1: ...ONS WITH THE USER Burley Appliances Ltd Lands End Way Oakham Rutland LE15 6RB Telephone 44 0 1572 756956 Fax 44 0 1572 724390 e mail info burley co uk web www burley co uk G4240Inst G20 31 Issue March...

Page 2: ...ST EVERY SINGLE GAS FIRE IT PRODUCES BURLEY IS IN THE UNIQUE POSITION OF KNOWING THAT EVERY APPLIANCE LEAVES THE FACTORY IN PERFECT WORKING ORDER Fireguards A fireguard is not supplied with this appli...

Page 3: ...l should cease and be replaced with the ticking sound of the spark igniter When the pilot flame is lit the igniter will stop another acoustic signal will confirm the pilot has been established if the...

Page 4: ...ceiver unit to its original position REPLACE THE HEATSHIELD over the unit Press here and slide down CAUTION With the exception of battery replacement the battery holder must be located within the heat...

Page 5: ...urn slowly anticlockwise to the ignition position A click will be heard and the pilot under right side of fuel bed should light If it does not repeat the operation a few times to purge any air in the...

Page 6: ...ift the control lever to the top of its travel 6 The off position on the side of the fire may not correspond exactly with the control lever This is only intended as an indication 1 12 Battery Replacem...

Page 7: ...the carton for damage before unpacking If it is obviously damaged consult the supplier as to whether to proceed with the installation 2 2 Make sure the carton is stood upright and open the top Remove...

Page 8: ...cubic feet ft to cubic metre m divide the room volume in cubic feet by 35 3 3 7 The appliance must not be installed in high rise blocks of flats bed sitting rooms basements which are not open on at l...

Page 9: ...o SPACERKIT and can stand directly against a wall Care should be taken with wall coverings as it may discolour them over time 4 3 The fire comes with a 60mm spacer fitted to the front trim we recommen...

Page 10: ...from the cavity causing heat build up on the fire surround back panel or moisture ingress from the cavity 4 12 Any under grate draught devices must be sealed off 4 13 If using the fire in a hole in t...

Page 11: ...tags clip onto the enamelled glass rails 6 4 DO NOT ATTEMPT TO USE THE APPLIANCE WITH BROKEN DAMAGED GLASS OR COALS Contact our service department 01572 756956 6 5 Decide upon the route for the gas su...

Page 12: ...ay Do not force the valve cable plug when inserting into the receiver it only fits one way HT Lead SW yellow TC red Valve Cable Fit four AA 1 5V batteries into the receiver unit and the PP3 9V battery...

Page 13: ...on every other gas appliance in the house and re check the pressure The pressure must still be within the tolerance of 1mb Now turn off all the other gas appliances and turn the fire down to pilot on...

Page 14: ...atures 13 o c 45 o c but for more accurate monitoring of room temperature it is advised that the sensing bulb is removed from the fire and carefully moved to a cooler location up to 1 metre away takin...

Page 15: ...e burner assembly in the chassis Remove the burner tray and examine it for general condition Discolouration of the burner surface is normal Clean around the air inlet removing all lint in the area of...

Page 16: ...the manufacturer See the additional information on testing 11 PARTS LIST Part Part No Front Ceramic Coal COA4241F Rear Ceramic Coal COA4241B Oxypilot NG Check if SIT or Seagas Oxypilot LPG Check if SI...

Page 17: ...as efficient as it was when brand new Burley manages to achieve this by designing the fire to ensure that the catalytic converter is in exactly the right position for long life and maximum efficiency...

Page 18: ...y gas appliance must be serviced every year The appliance has not been subject to misuse accident or repaired or fitted by anyone other than a Gas Safe registered installer formerly CORGI or our own e...

Page 19: ...t is important to take a gas rate test over a reasonable period of time so that the capacity of the meter is used On low Input appliances such as our flueless this is even more critical because uncert...

Page 20: ...iglo fires are protected by UK patents 2193802 2240620 and 2256920 Other Patents Pending Burley Appliances Ltd Lands End Way Oakham Rutland LE15 6RB Tel 01572 725570 Fax 01572 724390 www burley co uk...

Reviews: