Maintenanceandtroubleshooting
10.2 cleaning of the device
• Activate the HOLD function (see chpt. 9.12.1) in the Calibration menu in order not to interrupt the
process during cleaning.
• Always use a cleaning product compatible with the materials from which the device is made.
• If magnetic particles are in the fluid to be measured, often clean the deposits on the conductivity sensor,
with a special cleaning agent.
• When cleaning the electrodes, ensure that you do not scratch their surface.
• Avoid dry storage of graphite electrodes during long interruptions in measurement in order not to
increase the response time when they are next used.
→
Regularly clean the electrodes on the conductivity sensor with a suitable product, depending on how dirty they are.
Please feel free to contact your Bürkert supplier for any additional information.
10.3 solving a problem
red
leD
current
output
transistor
output
icon message
displayed in the
info menu
possible cause
recommended action
ON
22 mA
depending
on
thresholds
ERR
+
"Sensor not
found"
The connection to the
measurement module is
interrupted.
→
Switch the power
supply off then on
again.
→
if the error persists,
return the device to
Bürkert.
ON
22 mA
depending
on
thresholds
ERR
+
"S EE Fact
Read"
Factory data is lost.
The device continues to
measure but with a bad
accuracy.
→
Switch the power
supply off then on
again.
→
if the error persists,
return the device to
Bürkert.
"S EE FactI
Read"
ON
22 mA
depending
on
thresholds
ERR
+
"S EE User
Read"
User data for the sensor
is lost.
→
Switch the power
supply off then on
again.
→
check the sensor
parameters in all the
"Sensor" menus then
save them again.
→
if the error persists,
return the device to
Bürkert.
"S EE User
Write"
English
Type 8222 ELEMENT