Technicaldata
6
TEchNicAL DATA
6.1
conditions of use
Ambient temperature
–10...+60 °C
Air humidity
< 85%, without condensation
use
Indoor and outdoor
▶
Protect the device against electromagnetic interference, ultravio-
let rays and, when installed outdoors, the effects of the climatic
conditions.
ip-code
1)
not evaluated by UL
IP67
1)
and IP65
1)
according to IEC / EN 60529
Mating connectors must be wired, plugged, and tightened.
Housing lid must be fully tightened and locked
operating condition
Continuous operation
equipment mobility
Fixed device
Degree of pollution
Degree 2 according to UL/EN 61010 -1
installation category
Category I according to UL/EN 61010-1
maximum height above sea level
2000 m
6.2
conformity to standards and directives
The applied standards, which verify conformity with the EU directives, can be found on the EU-type examination
certificate and/or the EU declaration of conformity (if applicable).
6.2.1
conformity to the pressure Equipment Directive
▶
Make sure that the device materials are compatible with the fluid.
▶
Make sure that the pipe DN is adapted for the device.
▶
Observe the fluid nominal pressure (PN) for the device. The nominal pressure (PN) is given by the device
manufacturer.
The device conforms to Article 4, Paragraph 1 of the Pressure Equipment Directive 2014/68/EU under the fol-
lowing conditions:
• Device used on a piping (PS = maximum admissible pressure; DN = nominal diameter of the pipe)
type of fluid
conditions
Fluid group 1, Article 4, Paragraph 1.c.i
DN
≤
25
Fluid group 2, Article 4, Paragraph 1.c.i
DN
≤
32
or PSxDN
≤
1000 bar
Fluid group 1, Article 4, Paragraph 1.c.ii
DN
≤
25
or PSxDN
≤
2000 bar
Fluid group 2, Article 4, Paragraph 1.c.ii
DN
≤
200
or PS
≤
10 bar
or PSxDN
≤
5000 bar
English
Type 8222 ELEMENT