Bürkert 2861 Operating Instructions Download Page 2

1. 

OPERATING INSTRUCTIONS

The operating instructions contain important information.

•  Read the instructions carefully and follow the safety instructions 

in particular, and also observe the operating conditions. 

•  Keep the instructions in a location where they are available to 

every user.

•  The liability and warranty for the proportional valve are void if the 

operating instructions are not followed.

2. 

INTENDED USE

The  direct-acting  proportional  valve  can  be  used  as  an  actuating 

element for the process control. 
•  Do not use in potentially explosive areas.
•  Do not use outside. 
•  Operate only when in perfect condition and pay attention to correct 

storage, transportation, installation and operation.

•  Do not make any internal or external changes.

3. 

BASIC SAFETY INSTRUCTIONS

These  safety  instructions  do  not  make  allowance  for  any  contin-

gencies and events which may arise during installation, operation 

and maintenance.

WARNING!

Danger – high pressure!

•  Before loosening lines or valves, turn off the pressure and vent 

the lines.

Risk of burns/risk of fire if used continuously through hot 

device surface!

•  Keep the proportional valve away from highly flammable sub-

stances and media and do not touch with bare hands.

•  Do not obstruct the heat release required for operation.

To prevent injury, ensure the following:

•  Secure equipment/device from unintentional actuation.
•  Only trained technicians may perform installation and mainte-

nance work.

•  After an interruption in the power supply, ensure that the pro-

cess is restarted in a controlled manner.

•  Observe the general regulations of technology.

Electrostatic sensitive components/modules!

Observe the requirements in accordance with EN 61340-5-1 and 

5-2 to minimize/avoid the possibility of damage caused by a sudden 

electrostatic discharge!

4. 

TECHNICAL DATA

4.1.  Operating conditions

CAUTION!

Malfunction in unauthorized temperature range.

•  Avoid exceeding or dropping below the temperature range.

Ambient temperature:  

0 ... +55 °C  

Medium temperature:  

-10 ... +90 °C

Media: neutral gases, technical vacuum
Protection class:   IP65 in accordance with DIN EN 60529

4.2.  Mechanical and pneumatic data

Materials, pressure range, line connectors: see rating plate

4.3.  Electrical Data 

Operating voltage, power input: see rating plate. 

Nominal operating mode: Long-term operation ED 100 % in 

accordance with DIN EN 60034-1 

Electrical connection: (depending on type and design) wires, plug 

tabs in accordance with DIN EN 175301-803 shape A, shape B

5. 

INSTALLATION 

WARNING!

Risk of injury from high pressure in the equipment.

•  Before loosening lines or valves, turn off the pressure and vent 

the lines.

Installation position: any position, preferably with actuator above.

 

Clean pipelines and flange connections.

 

Install  dirt  filter  in  the  direction  of  flow  in  front  of  the  valve  

(mesh size 0.02 – 0.4 mm; according to orifice).

WARNING!

Danger from medium!

•  Make sure that the supplied seal fits properly.

 

Insert seal into valve.

NOTE!

•  The proportional valve must not be removed and the central 

adjusting screw must not be adjusted.

Screwing in pipeline:

NOTE!

•  Use suitable tool (open-end wrench) 

and do not use coil as a lever arm.

 

Hold the proportional valve on the fluid 

housing using an open-end wrench.

 

Screw in pipeline.

 

Check installation for leaks.

Attaching the mounting plate:

 

Fastening screws (2)

Mounting plate

mm* 

*

 Coil size

Tightening torque 

according to coil size: 
20 mm = max. 1.0 Nm 

32 mm = max. 1.2 Nm 

49 mm = max. 1.5 Nm

Connecting device socket:

 

Seal

max. 

0.9 Nm

NOTE!

•  Note the voltage and current 

type as specified on the rating 

plate. Ensure that the seal is fitted 

correctly.

 

Insert seal. 

 

Attach device socket and secure 

with screw.  

Tightening torque max. 0.9 Nm.

 

Connect protective conductor.

6. 

MAINTENANCE 

Under normal operating conditions, the valve is maintenance-free. 

7. 

MALFUNCTIONS

If malfunctions occur, check
•  the line connectors,
•  whether the operating pressure is within the permitted range,
•  the power supply and valve control.

8. 

TRANSPORTATION, STORAGE, DISPOSAL

•  Transport and store the proportional valve in shock-resistant 

packaging to protect against moisture and dirt.

•  Permitted storage temperature: -20 … +70 °C.
•  Dispose of the device and packaging according to the appli-

cable disposal and environmental protection regulations.

Type 2861 ... 2875

English

Summary of Contents for 2861

Page 1: ...ormalement fermée II TYPE PLATE TYPENSCHILD PLAQUE SIGNALÉTIQUE Observe the voltage current type and pressure specified on the type label Die auf dem Typenschild angegebene Daten für Spannung Stromart und Druck beachten Observer les données indiquées sur la la plaque signalétique pour la tension le type de courant et la pression MADE IN GERMANY 2873 A 2 0 FKM MS G1 4 PNVAK 8bar 24V DC 9W 001084 W1...

Page 2: ...cuum Protection class IP65 in accordance with DIN EN 60529 4 2 Mechanical and pneumatic data Materials pressure range line connectors see rating plate 4 3 Electrical Data Operating voltage power input see rating plate Nominal operating mode Long term operation ED 100 in accordance with DIN EN 60034 1 Electrical connection depending on type and design wires plug tabs in accordance with DIN EN 17530...

Page 3: ...umstemperatur 10 90 C Medien neutrale Gase technisches Vakuum Schutzart IP65 nach DIN EN 60529 4 2 Mechanische und pneumatische Daten Werkstoffe Druckbereich Leitungsanschlüsse siehe Typschild 4 3 Elektrische Daten Betriebsspannung Leistungsaufnahme siehe Typschild Nennbetriebsart Dauerbetrieb ED 100 nach DIN EN 60034 1 Elektrischer Anschluss abhängig von Typ und Ausführung Litzen Steckerfahnen na...

Page 4: ...selon DIN EN 60529 4 2 Caractéristiques mécaniques et pneumatiques Matériaux plage de pression raccords de conduite voir plaque signalétique 4 3 Caractéristiques électriques Tension de service puissance absorbée voir plaque signalétique Mode opératoire nominal fonctionnement continu ED 100 selon DIN EN 60034 1 Raccordement électrique en fonction du type et de la version torons barettes de raccorde...

Reviews: