9
TechnicalData
Type 2380
7.
TECHNICAL DATA
7.1.
Conformity and standards
In accordance with the EC Declaration of conformity, the device is
compliant with the EC Directives.
Several approvals such as FDA, EC Regulation No 1935/2004, USP,
ATEX and others can be provided, depending on the characteristics
of the ordered device.
7.2.
Type label
Type label for Type 2380 (by the cap of the device, see „Fig. 1“)
Several features of type code
Pressure of medium in bar
*)
Control air pressure in bar *)
Operating voltage, if applicable
communication
Serial no. S/N CE (or other) marks
ID-No.
Date of manufacture (encoded)
Bar code
Control function Orifice Sealing material
Controller type
Type Body material
Fig. 2: Type label 2380 - example
*)
all pressure values are listed as
overpressure
relating to atmospheric pressure in bar
7.3.
Operating conditions
WARNING!
Risk of injury by ignoring the permitted operating conditions!
Important device-specific technical specifications are indicated on
the type label.
▶
Observe permitted operating conditions printed on the device
type label.
Ambient temperatures:
-10 ... +55 °C
*)
Media:
liquids and gases (ultrapure, sterile, dirty,
aggressive, abrasive or even highly viscous),
steam for sterilization only
*)
Media temperatures
: 0 ... +80 °C
(-10 °C ... +150 °C at limited operating
conditions
*)
)
Media pressure:
vacuum ... 6 bar
**)
*)
media pressure max. 4 bar,
up to +134 °C: max. 60 min, ambient temperature max. +40 °C,
up to +150 °C: max. 30 min, ambient temperature max. +35 °C
**)
all pressure values are listed as
overpressure
relating to atmospheric pressure in bar