6
Service life
High switching frequency and high pressures
reduce the service life
Permitted medium temperature depending on seal material
Seal material
Medium temperature
NBR
-10...+90 °C
FKM
-10...+100 °C
Permitted media depending on seal material
Seal material
Permitted media
NBR
Neutral media such as compressed air, illuminating
gas, water, hydraulic oil, oils and grease without
additives
FKM
Oxygen, hot air, hot oils, oils with additives, Per
solutions
4.3 conformity
In accordance with the EC Declaration of conformity, the solenoid
valve Type 0400 is compliant with the EC Directives (if applicable).
4.4 standards
The applied standards, which verify conformity with the EC Directives,
can be found on the EC-Type Examination Certificate and / or the EC
Declaration of Conformity (if applicable).
4.5 Type label (example)
Type
Circuit function
Orifice
Seal material
Body material
Identity number
Date of manufacture
Voltage, Frequency, Power
consumption
EC mark (if applicable)
Connection thread, Operating
pressure
0400 A 12,0 NBR MS
Made in Germany
00041404
W12MN
230V 50-60 Hz 8 W
G1/2 P
N 1
-16 bar