General settings - Parameter
13.11
Disable or enable the diagnostics
•
If the diagnostics are enabled, the product gives information about the following items:
-
Monitoring of the measurement values.
-
Monitoring of product-internal parameters.
-
Status of the communication with the connected fieldbus.
By default, the diagnostics are enabled. The product status are shown according to
Table 8: Product status if the diagnostics are enabled
Product-status
indicator
Colour code
(for a PLC)
Displayed
symbol
Description
Meaning
Colour
Red
5
Failure, error,
malfunction
Due to a malfunction of the product
or its periphery, the measured
values can be incorrect
Orange
4
Function check
Ongoing work on the product. For
example, simulating measurement
values.
Yellow
3
Out of
specification
At least one of the monitored
parameters is outside its monitored
limits.
Blue
2
Maintenance
required
The product is in controlled oper-
ation; however, the function is
briefly restricted.
→
Do the required maintenance
operation.
Green
1
Diagnostics
active and no
event has been
generated
Messages are listed and possibly
transmitted through any connected
fieldbus.
Flashing rapidly
-
-
Identification
The product is selected using
a man-machine interface, for
example the Bürkert Communicator
software.
•
If the diagnostics are disabled, the product status changes are not shown. Refer to
Table 9: Product status if the diagnostics are disabled
Product-status
indicator
Colour code
(for a PLC)
Displayed
symbol
Description
Meaning
White
0
Diagnostics
inactive
Messages are neither listed nor
transmitted through any connected
fieldbus.
Flashing rapidly
-
-
Identification
The product is selected using
a man-machine interface, for
example the Bürkert Communicator
software.