19
Description
Type 8098 FLOWave L
5.7
Marking of the Unique Serial Number (USN)
The USN is marked on the side of the sensor. The USN is built with the device article number and the
device serial number.
5.8
Device status indicator
The device status indicator changes its colour based on the NAMUR NE 107 recommendation.
The color of the device status indicator gives the following pieces of information:
• Whether device diagnostics are active on not.
•
If device diagnostics are active, then the device status indicator shows whether diagnostics events have
been generated or not. If several diagnostics events have been generated, then the device status indicator
shows the diagnostics event with the highest priority. Refer to
.
If the device status indicator flashes, then the device is selected in a man-machine interface such as the
Bürkert Communicator software.
Table 1: Device status indicator in accordance with NAMUR NE 107, edition 2006-06-12
Colour
according to
NE 107
Colour code
(for a PLC)
Diagnostics event
according to
NE 107
Meaning
Red
5
Failure, error or
fault
Due to a malfunction of the device or its periphery,
the measured values can be incorrect.
Orange
4
Check function
Ongoing work on the device (for example, checking
the correct behaviour of the outputs by simulating
measurement values); the output signal is temporarily
invalid (e.g. frozen).
Yellow
3
Out of specification
The ambient conditions or process conditions for the
device are outside the permitted ranges.
Device-internal diagnostics point to problems in the
device or with the process properties.
Blue
2
Maintenance
required
The device continues to measure but a function is
temporarily restricted.
→
Do the required maintenance operation.
Green
1
-
Diagnostics are active and no diagnostics event has
been generated.
White
0
-
Diagnostics are inactive
English