19
Installation and removal
9.2.2
Solenoid coils with terminal box
green-yellow
black
black
Position
Terminal assignment
Protective conductor
Neutral conductor /
negative pole (-)
Phase / positive
pole (+)
Fig. 5: Terminal box
Screw
Circlip
Washer
Washer
Ring cable lug with supply
line
Fig. 6: Connection of external potential equalization
9.3
Removal
DANGER!
Risk of injury from high pressure.
▶
Before loosening the lines and valves, turn off the pressure
and vent the lines.
Risk of electric shock.
▶
Before reaching into the device, switch off the power supply
and secure to prevent reactivation!
▶
Observe applicable accident prevention and safety regulations
for electrical equipment!
WARNING!
Risk of injury from improper removal.
▶
Removal may be carried out by authorized technicians only
and with the appropriate tools.
Risk of injury due to media escaping from leaky connections.
▶
Seal the connection lines carefully.
→
Separate the electrical connections.
→
Separate the valve body from the pipeline.
NOTE!
Malfunctions due to dirt!
• Remove the old PTFE tape from the connections during re-
installs. Tape residue must not get into the pipeline.
english
AC10