16
Accessories
7.5.3
Electrical connection
Material
2)
:
Polyolefin
Temperature operating
range
2)
:
–55...+145 °C (–67...+293 °F) for fixed
installation
Minimum bending radius
2)
: 4 x external diameter for fixed installation
External diameter
2)
:
6.2 mm
Structure and function:
3 x stranded copper wire 0.5 mm² / LNPE
Halogen-free according to: IEC 60754-1
Variants
Code
Enclosure type
Permanently
installed cable
JJ04
+
JWxx
3)
This equipment must be mounted in
an UL/cUL AEx eb/Ex eb resp. AEx
tb/Ex tb enclosure certified for use
in Class I, Zone 1 resp. Zone 21.
Terminal box
90° with internal
thread M20 x 1.5
JA13 Type 1
Terminal box
90° with internal
thread NPT1/2
JA23 Type 1
Terminal box
45° with internal
thread M20 x 1.5
JA16 Type 1
Terminal box
45° with internal
thread NPT1/2
JA26 Type 1
Tab. 9: Electrical connection
2)
Specifications as per the manufacturer
3)
Different cable
lengths
8
ACCESSORIES
8.1
Cable gland for terminal box
Device must be installed in accordanc with Article 505
and 506 of the National Electrical Code (ANSI/NFPA 70)
for installation in the United States, or Section 18 of the
Canadian Electrical Code for installations in Canada. Note
that the operating temperature of the cable gland must be
at least 15 K above the maximum ambient temperature.
8.2
External grounding connection for
terminal box
If solenoid coils feature a terminal box, connection terminals are
enclosed for the external grounding connection.
If the potential equalization is not to be connected by a pipeline or
by the use of a plastic fitting, the connection can be made via the
external grounding connection. Its use is therefore optional and
must be assessed by the operator.
The connection capacity of the ring cable lug is 4...6 mm
2
and the
tightening torque is 1.2 Nm. The connection is made as shown in
english
AC10