00 ATEX 2129 X - 9
english
Coils suitable for individual or battery installation
NOTE
When installing a battery, the following data must be complied with
for the valves:
Dimensions of the valve housing
32 mm x 32 mm x 10 mm
Valve housing material
Brass (Ms),
Stainless steel (VA) or
Plastic (PA 6 GV)
Universal current, Nominal voltage 12...400 V, Frequency 0...60 Hz
Type designation
Rated
current [A]
Power
limit
[W]
Max.
permissibl-
e ambient
temperatu-
re [°C]
Tempeat-
ure class
For battery
installation:
min.
distance
form the
wall [mm]
AC10 - .. - 5 - PD73
0,68 ... 0,02
7
-30 ... +40
T4
1
AC10 - .. - 5 - PD74
0,25 ... 0,007
3
-30 ... +50
T5
1
AC10 - .. - 5 - PD75
0,19 ... 0,005
2,25
-30 ... +40
T6
1
AC10 - .. - 5 - PD76
0,114 ... 0,003 1,25
-30 ... +60
T6
1
AC10 - .. - 4 - PD77
0,33 ... 0,01
4
-30 ... +40
T5
5
AC10 - .. - 4 - PD78
0,25 ... 0,007
3
-30 ... +50
T5
5
AC10 - .. - 4 - PD79
0,13 ... 0,003
1,5
-30 ... +55
T6
5
AC10 - .. - 5 - PD80
0,68 ... 0,02
7
-40 ... +40
T5
1
AC10 - .. - 5 - PD81
0,25 ... 0,007
3
-40 ... +50
T5
1
AC10 - .. - 5 - PD82
0,19 ... 0,005
2,25
-40 ... +40
T6
1
AC10 - .. - 5 - PD83
0,114 ... 0,003 1,25
-40 ... +60
T6
1
AC10 - .. - 4 - PD84
0,33 ... 0,01
4
-40 ... +40
T5
5
AC10 - .. - 4 - PD85
0,25 ... 0,007
3
-40 ... +50
T5
5
AC10 - .. - 4 - PD86
0,13 ... 0,003
1,5
-40 ... +55
T6
5
Summary of Contents for AC10 4-PD56 Series
Page 46: ...44 00 ATEX 2129 X fran ais...
Page 48: ...46 00 ATEX 2129 X...
Page 49: ...00 ATEX 2129 X 47...
Page 50: ...48 00 ATEX 2129 X...
Page 51: ...00 ATEX 2129 X 49...
Page 52: ...50 00 ATEX 2129 X...
Page 53: ...00 ATEX 2129 X 51...
Page 54: ...52 00 ATEX 2129 X...
Page 55: ...00 ATEX 2129 X 53...
Page 56: ...54 00 ATEX 2129 X...
Page 57: ...00 ATEX 2129 X 55...
Page 58: ...56 00 ATEX 2129 X...
Page 59: ...00 ATEX 2129 X 57...
Page 60: ...58 00 ATEX 2129 X...
Page 61: ......
Page 66: ......
Page 67: ......
Page 68: ...The smart choice of Fluid Control Systems www buerkert com...